All Steel Class II B2 Biological Safety Cabinet

Model: BSC-1000IIB2 / BSC-1300IIB2 / BSC-1600IIB2

The bio-safety cabinet is a box-shaped air purification negative pressure safety device that prevents aerosols from containing dangerous or unknown biological particles during handling.

Its working principle is mainly to pump the air inside the cabinet to keep the negative pressure state inside the cabinet to protect the operator through the vertical air flow. The outside air is filtered through the HEPA filter and then enters the safety cabinet to avoid contamination of the sample. The air in the cabinet is also filtered through the HEPA filter and then vented to the atmosphere to protect the environment.

Color Option: White+Blue; White+Orange

Characteristics of All Steel Class II B2 Biological Safety Cabinet

  1. Air curtain isolation design prevents cross-contamination; 100% external airflow; negative pressure laminar flow; requires ductwork installation.
  2. Vertically sliding glass door; can be positioned arbitrarily, easy to operate, and can be completely closed for sterilization; height limit alarm indicator.
  3. Power output socket in the work area; equipped with waterproof socket and drain interface for operator convenience.
  4. HEPA filter at the exhaust vent to control emissions.
  5. Work environment ensures no pollution leakage; made of high-quality 304 stainless steel, smooth, seamless, and without dead corners, allowing for easy and thorough disinfection and preventing corrosion from corrosive agents and disinfectants.
  6. LED panel control; built-in UV lamp protection device; UV lamp only operates when the front window and fluorescent lamp are closed; UV timer function included.
  7. 10° tilt angle, ergonomically designed.

Technical Parameters of All Steel Class II B2 Biological Safety Cabinet

Model ParameterBSC-1000IIB2BSC-1300IIB2BSC-1600IIB2
Airflow system100% air exhaust
Cleanliness gradeHEPA: ISO 5 (Class100)
Number of colonies≤0.5pcs/dish·hour (Φ90mm culture plate)
Wind speedAverage suction wind speed: ≥0.55±0.025m/sAverage descending wind speed: ≥0.3±0.025m/s
Filtration Level / Filtration EfficiencyHEPA of borosilicate glass fiber material: ≥99.995%, @0.3μmOptional ULPA: ≥99.9995%
Noise≤65dB(A)
Illumination≥800Lux
Vibration half peak≤5μm
Power supplyAC single phase 220V/50Hz
Maximum power consumption500W600W700W
Weight210KG250KG270KG
Internal Size (mm)        W*D*H1040*650*6201340*650*6201640*650*620
External Size (mm)         W*D*H1200*800*22701500*800*22701800*800*2270
High efficiency filter specification and quantity980*490*50*1,
520*380*70*1
1280*490*50*1,
820*380*70*1
1580*490*50*1,
1120*380*70*1
Specification and quantity of fluorescent lamp/UV lamp20W*2/20W*130W*2/30W*130W*2/30W*1

All Steel Class II B2 Biological Safety Cabinet Display