Features of GC1290/MS8100 Gas Chromatography-Mass Spectrometer
- Inlet vacuum
- Ion Source: EI (electron ionization) standard
- High performance GC1290 gas chromatography, with EPC system and 7 inch touch screen display
- Clarity software, comply with GLP/FDA-21 CFR Part11

Structure of GC1290/MS8100 Gas Chromatography-Mass Spectrometer
- Sample Introduction
- Ion Source(EI Standard)
- Quadruple Mass Analyzer
- Detector(Electro Multiplier)

Specifications of GC1290/MS8100 Gas Chromatography-Mass Spectrometer
| Data processing system | |
| Data acquisition and processing platform | multi-core parallel processing technology and high-speed electronic circuit design |
| Software | customized Clarity software |
| SIM/Scan | SIM/Scan Data synchronization acquisition |
| SIM/Scan Data synchronization acquisition | guarantees full mass range scanning during full analysis time without significant loss of sensitivity |
| NIST library optional | |
| Software fully supports GLP/FDA-21CFR Part11 electronic signature certification, data validity security, system certification tool (IQ/OQ) and system suitability test (SST) requirements | |
| Mass spectrometer | |
| Ion source | high transmission efficiency Focusing inert EI source |
| Ion source temperature | 50-350 °C |
| Electronic energy | 0-300eV |
| Filament emission current | 0-300µA |
| Mass filter | quadrupole |
| Mass range | 1.5-1100 u |
| Mass shaft stability | better than ±0.10 u/48 hours |
| Detector | Triple off-axis detector with long-life electron multiplier |
| Full scan mode (SCAN) maximum time unlimited | |
| The foreline pump uses mechanical pump of not less than 130L/min, and the high vacuum uses turbomolecular pump of not less than 70L/s | |
| Gas chromatography | |
| Column oven control system | |
| Temperature range | 5 ° C ~ 420 ° C (increment 0.1 ° C) |
| Temperature control accuracy of the oven | better than ±0.05 °C (measured at 200 °C) |
| Program temperature control | 20 ramps / 21 platform program temperature, software operation ramp is unlimited |
| Maximum rate of program increase | 80 ° C / min (increment 0.1 ° C) |
| Cooling speed | 350℃~100℃≤3min |
| Carrier gas control system | |
| Outlet connection method | atmospheric pressure and vacuum mode |
| Number of carrier gas pressure blocks | 3 segments |
| Carrier gas flow program number | 3 segments |
| Flow range | 0~1000mL/min(He, H2),(Factory default:He) 0~200mL/min(N2,Ar), (Factory default: N2) |
| Tail blow | 0~100mL/min |
| Reference gas | 0~150mL/min |
| Pressure range | 0~100psi |
| Set resolution | 0.01psi |
| Maximum split ratio | 5000:1 |
Accessories optional
- Auto sampler
AS-20(22 sample places) PAL LSI 850 (54*3 sample places)(From CTC Analytics, Switzerland)
- Eclipse 4760 Purge & Trap Sample Concentrator (From OI, USA)
Customized for MSQ8100 GC/MS, used for VOCs in water and soil
4551A (water sample), 4100(water/soil sample)autosampler is optional

- GC1290 MS8100 Accessories (1)
- GC1290 MS8100 Accessories (2)
- GC1290 MS8100 Accessories (3)
- GC1290 MS8100 Accessories (4)
- GC1290 MS8100 Automatic sampler (optional accessory) (1)
- GC1290 MS8100 Automatic sampler (optional accessory) (2)
- GC1290 MS8100 Automatic sampler (optional accessory) (3)
GC1290 MS8100 Display
- Outer box packaging
GC1290MS8100+ Autosampler- GC1290MS8100+ Autosampler