K5800/K5800C Nano Spectrophotometer (with cuvette)

The K5800/K5800C nano spectrophotometer is a new full-wavelength ultra-micro spectrophotometer, which can be used to detect nucleic acids, proteins, cell solutions, microarray samples, and conventional full-wavelength scanning. At the same time, there are a dark room and a detection platform, and you can choose two measurement modes: cuvette and detection platform.

Characteristics of K5800/K5800C Nano Spectrophotometer

  1. The optical fiber is built-in to avoid the optical fiber breakage caused by the external force collision and the measurement results in confusion
  2. The measurement results are saved in spreadsheet mode
  3. Less sample usage
  4. No need for a cuvette
  5. No need to heat, test at any time when starting up
  6. Fast detection speed
  7. Direct display of concentration value, absorbance value, the ratio of 260/230 and 260/280
  8. The sample does not need to be diluted, and the detectable concentration range is 50 times that of a conventional ultraviolet-visible spectrophotometer
  9. Simple operation and easy to use

Parameters of K5800

  • Light source: long-life pulsed xenon flash lamp
  • Detector: 2048-element linear silicide CCD array
  • wavelength range: 190 ~ 850nm
  • wavelength accuracy: ± 1nm
  • Wavelength resolution: 2 nm (FWHM at Hg 546 nm)
  • Repeatability: <± 0.5nm
  • Lightpath: 1mm, 0.05mm (optical path automatic conversion)
  • nucleic acid measurement range: 0.4 ~ 15000ng / μl (DS-DNA)
  • Protein measurement range: 0.01 ~ 400mg / ml (BSA)
  • sample volume requirements: 0.3 ~ 2 μL
  • Absorbance Accuracy: 1% (0.76 absorbance at 350 nm)
  • Absorbance range: 0.002 – 300 (equivalent to 10mm path length)
  • cuvette mixing system: own mixing system so that the sample concentration is more uniform
  • Sample measurement time: less than 5 seconds
  • Sample base material: stainless steel and quartz fiber
  • cuvette specifications (optical path): 1mm, 2mm, 5mm, 10mm
  • The minimum sample volume of the cuvette: 20 μl
  • The minimum height of the cuvette sample is 5mm
  • Cuvette Type: A cuvette with a traceable cuvette specification
  • Cuvette Anechoic Chamber: A standard cuvette darkroom with a wide variety of cuvettes
  • mixing system: comes with a mixing system
  • temperature control: 4 ~ 42 ℃ thermostat adjustable temperature error <± 0.5 ℃
  • through the USB port or network dump data
  • without preheating, boot at any time detection
  • with a liquid column to determine the abnormal function
  • with automatic measurement function, simplifying the operation process
  • permanent preservation of data, at any time to export or delete data
  • built-in wifi, remote operation can be achieved
  • The test result can be printed wirelessly
  • built-in detection system; comes with a high-definition display, the touch screen operation

K5800C Cuvette Parameters

  1. Cuvette specifications (optical path): 1mm, 2mm, 5mm, 10mm
  2. Minimum sample volume of the cuvette: 20 μl
  3. The minimum height of the cuvette sample is 5mm
  4. Cuvette Type: A cuvette with a traceable cuvette specification
  5. Cuvette Anechoic Chamber: A standard cuvette darkroom with a wide variety of cuvettes
  6. Mixing system: comes with a mixing system
  7. Temperature control: 4 ~ 42 ℃ thermostat adjustable temperature error <± 0.5 ℃

K5800/K5800C Nano Spectrophotometer Display