DW-8000 Handheld XRF Gold Analyzer

The DW series analyzers are configured with powerful miniature X-ray tubes, Si-PIN detectors or highly advanced silicon drift detectors (SDDs), specialized filters, and multibeam optimization for the ultimate in XRF field analysis. The actual overall value of the DRAWELL analyzer is embodied in the following: it can make correct decisions in real-time without relying on laboratory tests far away from the detection environment.

Features of DW-8000 Handheld XRF Gold Analyzer

  1. One-key power-on/off operation and automatic calibration without manual operation;
  2. 45s from startup to testing, and 0.8s reading of the grade and other data;
  3. One-key sample testing, with software for automatic timing lock and stop;
  4. Automatic X-ray shutdown within 2s in the absence of samples in front of the test window.

Applications of DW-8000 Handheld XRF Gold Analyzer

DW-8000 Handheld XRF Gold Analyzer application

Specifications of DW-8000 Handheld XRF Gold Analyzer

WeightDevice: 1.50kg, 1.65kg with battery.
Dimension250mm x 75mm x 270mm (L*W*H)
Excitation sourceHigh-power high-performance X-ray microtube
Target materialsFive target materials of X-ray tube available:gold (Au), silver (Ag), tungsten (W), tantalum (Ta) and palladium (Pd)
Voltage35kV-50kV voltage (changeable)
FilterA variety of selectable filters, automatically adjusted according to different tested objects
DetectorHigh-resolution Si-Pin detector
Detector refrigeration temperaturePeltier effect semiconductor refrigeration system
Standard filmExternal 316 standard film/window protection cover (Optional built-in standard film, plus version)
Power supply1 lithium battery (7.2v\6600mAh)
ProcessorHigh-performance ARM pulse processor
Data processing32G large-capacity data storage card: ≥80,000 sets of data and spectrograms;
Display screenHigh-resolution TFT industrial-grade colored high-definition touch screen, it is ergonomic, sturdy, dust-proof, and waterproof, clearly visible under any light conditions
Outline designThe integrated designed body is sturdy, waterproof, dustproof,antifreeze, shockproof, and can be used normally in harsh environments.
Safe operation“One key” detection, auto-lock, detection auto-stop functions. The X-ray will automatically be turned off if there is no sample in front of the detection window for 2 seconds. 3/2 of the shell of the device is covered with a 6061 aluminum alloy frame design, with better X-ray blockage.
Detection ReportCustomized detection report available as per the customers’ demands
Element analysisAu, Pt, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Hf, Ta, W, Pb, Bi, Zr, Nb, Mo, Cd, Sn, Sb, Re, In, Ag,Pd, Ru, Rh, Ir, etc.

DW-8000 Handheld XRF Gold Analyzer Display

DW-8000 Handheld XRF Gold Analyzer
DW-8000 Handheld XRF Gold Analyzer display2
DW-8000 Handheld XRF Gold Analyzer display