TD4ZA Tabletop PRP-PRF-CGF Centrifuge
TD4ZA is a multi-functional centrifuge, that can use for routine sample analysis in medical, hospital, pathology, and institutional laboratories. And also for the blood center, Dental hospital, Plastic surgery, Orthopedics department, and Maxillofacial Surgery.
Features of TD4ZA Centrifuge
1. Adopt the steel structure, which is safer, simple-compact, light-weight, and low-noise.
2. Digital display and LCD display for choose, adopt control system realizing microprocessor control, it control rotate speed, relative centrifuge force.
3. Maintenance-free frequency conversion motor, can prevent over-speed operation.
4. It’s widely used in qualitative analysis of blood serum, plasma, and medical products in hospitals, biochemistry and blood center, Dental hospital, Plastic surgery, Orthopedics department, and Maxillofacial surgery.
5. With a special program for PRP, PRF, CGF.



Technical parameters of TD4ZA Centrifuge
Model | TD4ZA | |||||
Max Speed | 4000r/min | |||||
NO.1 AngleRotor | 12*10ml | 4000r/min | 2680xg | |||
NO.2 Swing Rotor | 8*10/15ml | 4000r/min | 2680xg | |||
Program | No.1 | No.2 | No.3 | No.4 | ||
PRP | PRF | CGF | adjustable | |||
Motor | Microprocessor &Brushless DC Motor | |||||
Timer Range | 0~99min | |||||
Noise | ≤50dB(A) | |||||
Power Supply | AC220V&110V50Hz 2A | |||||
Dimension | 450*340*270mm(L*W*H) | |||||
Weight | 18kg |
What is CGF?
CGF (Concentrated Growth Factor) is extracted from autologous blood by our specialized variable speed centrifuge DL4-M. The concentration of growth factor is four times higher than that of normal blood active substances and it contains CD34 positive cells and white blood cells with high activity. CD34 positive cells are important Cells for promoting the reconstruction of the micro-circulatory system and collagen regeneration. In the mesoderm, filling and wound repair, micro-capillary and the micro-lymphatic system can be quickly reconstructed in the treatment.
CGF Application
1. Move skin wrinkles, Improve skin dryness, relaxation, dullness, spots, pore size and other phenomena.
2. Skin anti-aging
3. Promote tissue regeneration, Repair of wounds and scars
4. Reconstruction of skin barrier and repair of tissue
5. Lipid transplantation partners to improve the survival rate of fat transplantation
6. Scalp management
7. Treatment of mesodermal and osteoarthritis
CGF Therapy Advantages
- CGF from autologous blood, no rejection reaction
- No Chemical additives, it’s safer
- With Various concentrated growth factors, a good effect
- The CD34-positive white cells promote the micro-circulatory system and collagen regeneration
- Multiple clinical uses – liquid/gelatinous without embolism risk
Compare 3 Generation of Blood Active Substance PRP PRF CGF
Name |
Separate results |
Condition |
construction |
Molecular Structure |
PRP (Platelet Rich Plasma) |
PPP+PRP+RBC |
Anticoagulant |
Liquid |
Compact Tetramolecular structure |
PRF (Platelet Rich Fibrin) |
PPP+PRF+RBC |
No |
Gel Membrane |
3-dimension loose structure |
CGF (Concentrated Growth Factor) |
PPP+CFG+PRP+CD34++RBC |
No |
Liquid Gel Membrane Half-Gel |
3-dimension looser structure |
