DW-XRD-Y3500 X-ray Diffractometer
The new high-end X-ray diffractometer (XRD) is a domestic high-performance and high-precision XRD, which is the project of the National Development and Reform Commission. With advanced core technology, it can accurately do qualitative and quantitative phase analysis of metal and non-metallic polycrystalline samples. It can be mainly used in qualitative or quantitative analysis, crystal structure analysis, material structure analysis, macroscopic or microscopic stress determination, crystal size determination, crystal size determination, crystallinity determination, etc., therefore, It is widely used in many disciplines and industries: materials science, physics, chemistry, chemical industry, metallurgy, minerals, drugs, building materials, ceramics, etc.
The new high-end X-ray diffractometer (XRD) is a domestic high-performance and high-precision XRD, which is the project of the National Development and Reform Commission. With advanced core technology, it can accurately do qualitative and quantitative phase analysis of metal and non-metallic polycrystalline samples. It can be mainly used in qualitative or quantitative analysis, crystal structure analysis, material structure analysis, macroscopic or microscopic stress determination, crystal size determination, crystal size determination, crystallinity determination, etc., therefore, It is widely used in many disciplines and industries: materials science, physics, chemistry, chemical industry, metallurgy, minerals, drugs, building materials, ceramics, etc.
Base on this standard configuration, if we install related accessories, it can do analysis structure of thin films, texture of metal materials, stress measurement,and material structure under high and low temperature.
Within the most advanced technology at present, the accuracy of the goniometer had reached the current world advanced level. The X-ray source and detector can work stably for a long time to ensure the accuracy of measurement of diffraction peak position, peak shape and intensity. Phase structure analysis, including: phase content, grain size judgment, crystallinity, austenite content, cell measurement, second class stress calculation, diffraction line indexing, phase structure analysis,thin film material analysis, small angle particle size analysis, etc. DW-XRD-Y3500 includes high-stability X-ray generator, high-precision goniometer, scintillation detector, data processing software, and related application software.
Features of DW-XRD-Y3500
- High-frequency and high-voltage X-ray source: Solid X-ray generator greatly improves the stability of the measurement results of the XRD;
- Long life X-ray tube: metal ceramic X-ray tube, with good heat dissipation, high operating power (40kV×40mA), long service life;
- High precision goniometer: It is controlled by optical coding technology. Based on the traditional turboworm transmission technology, incremental optical coding technology is adopted. The optical digital coding can directly read the angle from both arms (invention patent), which greatly improves the accuracy and repeatability of the goniometer. The new generation of direct optical coding systems ensures the accuracy of the goniometer over the life of the instrument through the accurately calibrated Heidenhain optical encoder and trajectory tracking technology.
The goniometer adopts “coaxial &different core” technology to avoid the interference between the arms during scanning, ensuring the accuracy and stability of the goniometer.
- Multiple XRD accessories: high temperature, low temperature, multi-function and other XRD accessories installation to achieve “plug and play”, software automatic identification control technology, convenient for operators to use the instrument;
- Safe X-ray protection: X-ray scattering line protection device is more safe and reliable, the X-ray protection door is forbidden to open when the sample is measured, and double protection can avoid the operator from scattering line radiation under any circumstances.

Parameters of DW-XRD-Y3500
Model | DW-XRD-Y3500 |
High frequency high voltage solid X-ray generator | |
Maximum output power | 3kW |
Tube voltage | 10 ~ 60KV, 1kV/step |
Tube current | 5 ~ 50mA, 1mA/step |
Beam voltage stability | Better than ±0.005% (when the external voltage fluctuates 10%) |
X-ray tube | Metal-body ceramic X-ray tube |
Focus size | Focus 1×10mm |
Standard target | Cu target (other target is optional) |
Ray tube power | 2.4kW |
High precision goniometer | |
Goniometer | Vertical type,θ/θ,sample is placed horizontally |
Using incremental coded reading technology | |
Diffraction circle radius | 180mm ~ 300mm |
Scanning mode | continuous, step-by-step |
2θ Measuring range | -110°~ 168° |
Minimum step Angle | 0.0001° |
Maximum rotational speed | 20°/s |
Diffraction Angle measurement linearity | ≤0.01° |
Full spectrum Angle measurement accuracy | ±0.005° |
Beam size | 180×180μm |
Resolution | ≤0.028° (2θ center) |
Repeatability error | ±0.0001° |
Angle reproducibility | 0.0001° |
Maximum positioning speed | ≤1200°/min |
Diffraction angular linearity | The angular deviation of all peaks in the full spectrum does not exceed ±0.01°. |
Detector | |
Scintillation detector | It Works with monochromator to effectively remove the Kβ line |
Maximum linear count | ≥5×105CPS |
Spectral resolution | ≤50% |
Curved crystal graphite monochromator | When testing the sample, a monochromator is required to effectively remove the Kβ line, and the reflection efficiency is ≥28% |
Control and data processing software | |
Computer | Control and data processing software running under the Windows10 operating system. |
Application software | Phase qualitative, quantitative analysis, Kα1, α2 stripping, full spectrum fitting, peak selection fitting, half-height width and grain size calculation, cell measurement, secondary stress calculation, diffraction line index, multiple plotting, 3D plotting, diffraction data calibration, background deduction, quantitative analysis without standard sample, full spectrum fitting (WPF), XRD diffraction pattern simulation. |
Overall dimensions | 1320×1150×1860mm |
Working Condition of DW-XRD-Y3500
- Working temperature: 10℃ ~ 30℃.
- Ambient relative humidity: ≤80%.
- Power supply: unidirectional, AC 220V, 50HZ, power supply voltage fluctuation does not exceed the rated voltage -10% ~ +10%, power capacity is not less than 5kVA.
- There should be a good grounding device, grounding resistance is not more than 4Ω.
- Cooling system: Independent self-circulating refrigeration system, using pure water.
- The power supply line shall not have arc and high-frequency interference caused by welding machines, high-frequency furnaces and other equipment.
- The surrounding environment should not have flammable and corrosive gases, and try to avoid dust and vibration.
Protection system
The protection system is safe and reliable, with machine and door interlocking mechanism. When operator open the door, at the same time the shutter stops working. This function can avoid the operator from being exposed to scattered ray radiation. The radiation dose < 0.2μSv/h.
Configuration List of DW-XRD-Y3500
Part | Name | Unit | Qty | Remark |
X-ray generator | ①AL20 High-frequency high voltage generator | Set | 1 | solid state |
②XD3560 High voltage cable(100kVP) | Piece | 1 | Length:3m | |
③XD3510 Tube sleeve(includes auto-shutter) | Set | 1 | ||
④XD3520 Auto-control unit | Set | 1 | power cable 1 piece | |
⑤XD3530 Cabinet | Set | 1 | Lead+ lead glass | |
⑥AL3540 Metal ceramic insulated X-ray tube | Piece | 1 | Cu target 2.4kW | |
Goniometer | ①XD3502 goniometer (θ-θ structure) | Set | 1 | |
②Slit, powder sample stage | Set | 1 | 1 set for each | |
③Through hole sample holder | Piece | 10 | Quartz matrix | |
④Blind hole sample holder | Piece | 30 | Quartz matrix | |
⑤filter | Piece | 1 | Match with the target | |
⑥X-ray path adjustment accessories | Set | 1 | ||
Record control unit | ①Scintillation counter | Set | 1 | |
②Recorder-controller | Set | 1 | ||
③Electrical machinery& communication cable | Set | 1 | 2 motor cables, 1 communication cable | |
④Power system | Set | 1 | ||
Cooling system | ①AL3 Circulating water cooling device | Set | 1 | unibody construction |
②Cooling water connection pipe | Piece | 2 | ||
PC | ①Intel i Series processor, 8G memory, 256G SSD, 24-inch LED display | Set | 1 | Dell |
②A4 laser printer | Set | 1 | ||
Control& application software | ①AL series XRD control software | Set | 1 | Windows11 |
②XRD data processing software | Set | 1 | ||
③Diffraction data card base | Set | 1 | ||
④Crystal Structure Data Base | Set | 1 | ||
Documents | ①User Manual | Copy | 1 | |
②Water cooling system instruction | Copy | 1 | ||
Spare parts | ①Fuse 1、2、3、5、10(A) | Piece | 10 | 10 for each |
②Tool | Set | 1 | ||
③Agate mortar Φ100 | Set | 1 | ||
④Graphite monochromator | Set | 1 | Reflectivity >28% |