Dissolved Oxygen(DO) Meter

What is Dissolved Oxygen Meter?

Dissolved oxygen meters are analytical instruments used to measure the amount of oxygen dissolved in a unit volume of water. Oxygen dissolves poorly and can only exist in water at low concentrations however it is still is essential for the respiration of a wide variety aquatic animals and bacteria. The accurate measurement of dissolved oxygen is critical to processes such as the making of compost tea, testing water quality, sewage treatment, river monitoring, fish farming, wine making many other applications where the amount of dissolved oxygen in water is important.

Features of Dissolved Oxygen Meter

  1. Waterproof and dustproof
  2. Intelligent and high precision
  3. Easy to operate and read
  4. Beautiful appearance
  5. Pocket, portable and benchtop available
  6. Automatic calibration, temperature compensation, data storage
Touch-screen Benchtop PH Meter-9

Applications of Dissolved Oxygen Meter

Dissolved Oxygen Meter uses two different metal electrodes in the electrolyte solution containing oxygen to produce a redox reaction. DO Meter is widely used in various fields.

  1. Agriculture
  2. Pharmaceuticals
  3. Food
  4. Industry
  5. Electricity
  6. Scientific Research
  7. Metallurgy
PH Meters Application

Specifications of Dissolved Oxygen Meter

Dissolved Oxygen Meter DO100T DO10 ORP+
Picture Touch-screen Benchtop PH Meter-6 DO10-_DOPro10-3 ORP+ (3)
Type Benchtop Portable Pocket
Features 1. 7″ TFT Touch screen 1. 3.7” Color screen 1. Bluetooth
2. IP54 dustproof and spillproof 2. IP57 Waterproof 2. IP67 Waterproof
DO Range 0-20.00 mg/L(ppm), 0-200.0 % 0~20.00 mg/L(ppm), 0~200.0 % /
Resolution ± 0.30 mg/L;0.01 or 0.1 mg/L 0.01 or 0.1 mg/L /
Accuracy / ± 0.30 mg/L /
ATC range (0 – 50)℃ automatically / /
Salinity compensation 0~45 ppt manual / /
Barometric compensation 0~200 kPa automatically / /
mV Range -1,999mV -+1,999mV / -1,000mV – +1,000mV
(ORP probe optional) Resolution ± 0.1/1mV / ± 0.1/1mV
  Accuracy ±0.03% FS ±1digit / ±0.1% FS ±1digit
Temperature Range 0-100°C / 0 to 50˚C (32-122˚F)
Resolution/Accuracy 0.1℃; ±0.2℃ / ±0.2˚C
Temp. compensation / 0~45 ℃ automatically /
Salinity compensation / 0~45 ppt manually /
Barometric compensation / 0~200 kPa automatically /
Data storage 500groups 3000 groups /
Power supply DC12V Rechargeable Lithium battery × 1 (2000mAh) 4×1.5V AAA alkaline batteries preinstalled
Packing including 1. DO100T Meter 1. Meter × 1 1. ORP+ Meter (Probe and 4×1.5V AAA alkaline batteries preinstalled)
2. DO01-2M Polarographic DO probe, cable length: 2m 2. POM DO electrode: DO01-2M-H × 1 2. 222mV ORP standard solution: 30ml
3. DOS-01 Membrane refill solution: 30mL,1pc 3. DO refill solution: 30mL× 1 3. 3.0mol KCl pH/ORP soaking solution, 10mL, 1 bottle
4. DOSC Sensor caps: 3pcs/group, 1pkg 4. DO replacement sensor caps: 3pcs 4. Sample Vials: 1pcs
5. F01 Flexible probe holder: 1pc 5. USB Type-C Charger Cable× 1 5. Lanyard: 1pc
6. Magnetic stirrer: 1pc 6. Hard carrying case×1 6. Hard carrying case: 1pc
7. PC cable: 1pc
8. A01 Power adaptor

Why Choose Us?

Order Process

order process of Automatic melting point meter

FAQ

– We are a factory.

  • Usually, MOQ is 1 piece.
  • The general MOQ differs greatly between different products if there is no stock. But the quantity still can be negotiated.

– Sample is available, but we do not provide free samples.

– OEM service is available with customer’s brand.

– We accept the payment by L/C, T/T, Paypal, Western Union, etc.

– Generally, it will take 7-15 working days after receiving your advance payment. Depend on the quantity.

– We could provide Online instruction; Real-time support by video call or voice chat; During warranty time, we can send product accessories when you need them for free; Technical guidance is free and ready forever.

– 1 year. it can be negotiated if you need an extended warranty.