What is Analytical Balance(0.1mg)?
An analytical balance (or lab balance) is a class of balance designed to measure a small mass in the sub-milligram range. The measuring pan of an analytical balance (0.1 mg resolution or better) is inside a transparent enclosure with doors so that dust does not collect and so any air currents in the room do not affect the balance’s operation.
This enclosure is often called a draft shield. The use of a mechanically vented balance safety enclosure, which has uniquely designed acrylic airfoils, allows a smooth turbulence-free airflow that prevents balance fluctuation and the measure of mass down to 1 μg without fluctuations or loss of product. Also, the sample must be at room temperature to prevent natural convection from forming air currents inside the enclosure causing an error in the reading. Single pan mechanical substitution balance is a method of maintaining consistent response throughout the useful capacity of the balance. This is achieved by maintaining a constant load on the balance beam and thus the fulcrum, by subtracting mass on the same side of the beam as which the sample is added.
Features of Analytical Balance(0.1mg)
1. Electromagnetic Force Compensation Technology.
2. Aluminum Alloy die cast base and ss platter.
3. Super Bright LCD display with backlight.
4.RS232C Interface
5. Clear Glass Windshield as standard.
6. Overload protection, Bubble Level Adjustment, Under hook
7. Full capacity Subtraction
8.Multi Weighing unit conversation g/mg/ct/oz.
9. Stabilization Time, 2-3 seconds.
10. Check Weighing, Parts counting, percentage weighing
11. Universal power adaptor supplied as standard
12. Certificated calibration weight supplied as standard.
13. Internal calibration or external calibration for your choice.
Application of Analytical Balance(0.1mg)
Laboratory balances from a general standpoint measure the mass of an object, in the laboratory, they are used to measure solids, liquids, and tissue, and they have a wide range of uses in virtually any laboratory including clinical, research, and environmental settings.
Specification of Product
(1)FA-E series
Model | FA1004E | FA1104E | FA1204E | FA2004E | FA2104E | FA2204E |
Picture | | | | | | |
Capacity(g) | 100g | 110g | 120g | 200g | 210g | 220g |
Resolution(g) | 0.0001g | |||||
Cal.weight | Internal Calibration | |||||
Min weighing(g) | 0.0004g | |||||
Stable Time | ≤3s | |||||
Display | LCD(white back light with black font) | |||||
Pan size | Φ80mm(standard) Φ90mm(optional) | |||||
Operation temp | 5-35℃ | |||||
Repeat ability | ±0.0002g | |||||
Liner | ±0.0003g | |||||
Dimension | 300X200X285mm | |||||
Draft shield size | 180x175x200mm | |||||
LCD Size | 96x24mm | |||||
Option | RS232C(standard)、 RS485/ USB/Printer(optional) | |||||
Packing size | 425x320x415mm | |||||
Gross weight | 8.0kg |
(2)FA-T series
Model | FA1004T/FA1004N-T | FA1204T/FA1204N-T | FA2004T/FA2004N-T | FA2204T/FA2204N-T | FA3004T/FA3004N-T |
Picture | | | | | |
Max.Capacity | 100g | 120g | 200g | 220g | 300g |
Min.Capacity | 10mg | 10mg | 10mg | 10mg | 10mg |
Readability | 0.1mg | ||||
Cal.weight | External Calibration/Internal Calibration | ||||
Linearity: | ±0.3mg | ||||
Repeatability: | ±0.1mg | ||||
Settling time: | ≤8sec. | ||||
Operating temperature: | 17.5℃~22.5℃,fluctuation range<1℃/h | ||||
Pan size: | Φ80mm | ||||
Output Interface: | RS232/USB | ||||
Windshield Size: | 225mm*220mm*265mm | ||||
Dimensions: | 340mm x 215mm x350mm | ||||
Net Wight: | 7200g | ||||
Power Supply | AC110-240V/Universal Adaptor DC5V-2A
| ||||
Scope of testing | 0-20.0000g/cm³ | ||||
Peeled Range | 0-20.0000g/cm³ | ||||
Measurement Precision: | 0.1mg/cm³ | ||||
Repeat Accuracy: | ±0.2mg/cm³ | ||||
Resolution: | 0.11mg/cm³ | ||||
Calibration Weight: | 100g | 200g |
(3)FA series
Model | FA1004/FA1004N | FA1204/1204N | FA2004/FA2004N | FA2204/FA2204N | FA3004/FA3004N |
Picture | |||||
Capacity: | 0-100g | 0-120g | 0-200g | 0-220g | 0-300g |
Readability: | 0.1mg | ||||
Cal.weight | External Calibration/Internal Calibration | ||||
Linearity: | ±0.2mg | ||||
Repeatability: | ±0.2mg | ||||
Pan size: | Φ80mm | ||||
Output Interface: | RS232 | ||||
Dimensions: | 340mm x 215mm x350mm | ||||
Net Wight: | 6800g | ||||
Power Supply | Universal Adaptor AC110-240V |