Biosafety Cabinet

Introduction

A biosafety cabinet (BSC)—also called a biological safety cabinet or microbiological safety cabinet—is an enclosed, ventilated laboratoryworkspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level. Several different types of BSC exist, differentiated by the degree of biocontainment required. The U.S. Centers for Disease Control and Prevention (CDC) classifies BSCs into three classes. These classes and the types of BSCs within them are distinguished in two ways: the level of personnel and environmental protection provided and the level of product protection provided. Class I cabinets provide personnel and environmental protection but no product protection. Class II cabinets provide both kinds of protection (of the samples and of the environment) since makeup air is also HEPA-filtered. The Class III cabinet, generally only installed in maximum containment laboratories, is specifically designed for work with BSL-4 pathogenic agents, providing maximum protection. The enclosure is gas-tight, and all materials enter and leave through a dunk tank or double-door autoclave.

  • Features
  • 1. 10°tilt design, more ergonomic.
  • 2. Vertical flow negative pressure machine type, A2: 30% of air is filtered and recycled, 70% air is filtered and then discharged into the room or connected to the exhaust system. B2: 100% air is filtered and then discharged into the room or connected to the exhaust system.
  • 3. Lighting and sterilization system safety interlock.
  • 4. HEPA high-efficiency filter can filter more than 99.99% of 0.3um dust particles.
  • 5. Digital display LCD control interface, fast, medium. Slow three speed.
  • 6. The working area is SUS304 brushed stainless steel, strong, durable, easy to clean, anti-corrosion.
  • 7. Standard configuration diameter 160mm, 1 meter long exhaust duct and elbow.
  • 8. Work area is equipped with a five-hole socket.

Application Areas

The primary purpose of a biosafety cabinet is to protect the operator and the surrounding environment from biological contaminants and other hazardous materials. There are various classes of biological safety cabinets, each defined by the required level of biosafety and containment as well as the required configuration of the cabinetry. The proper class and type is selected in accordance with the requirements for the specific application and level of bio-containment needed. It is widely used in scientific research, teaching, clinical testing and production in the fields of microbiology, biomedicine, genetic engineering, biological products, etc. It is the most basic safety protection equipment in the first-level protective barrier in laboratory biosafety.

 

 

 

Specification of Product

 

(1)Class II A2/B2 series

 

Model

BSC-1000IIA2/BSC-1000IIB2

BSC-1300IIA2/BSC-1300IIB2

BSC-1600IIA2/BSC-1600IIB2

 

 

 

 

Picture

Clean level

Grade 100(209 E U.S. Federal)

Grade 100(209 E U.S. Federal)

Grade 100(209 E U.S. Federal)

Number of bacteria

≤0.5per utensil.hour(90mm utensil)

≤0.5per utensil.hour(90mm utensil)

≤0.5per utensil.hour(90mm utensil)

Average wind speed

Inside the door

0.38±0.025 m/s

0.38±0.025 m/s

0.38±0.025 m/s

Middle

0.26±0.025 m/s

0.26±0.025 m/s

0.26±0.025 m/s

Inside

0.27±0.025 m/s

0.27±0.025 m/s

0.27±0.025 m/s

Front suction wind speed

0.55m±0.025m/s (70% air exhaust)/(100% air exhaust)

0.55m±0.025m/s (70% air exhaust)/(100% air exhaust)

0.55m±0.025m/s (70% air exhaust)/(100% air exhaust)

Noise

≤62dB(A)

≤62dB(A)

≤62dB(A)

Working area dimension(W*D*H)

1000*650*620mm

1300*650*620mm

1600*650*620mm

Overall dimension(W*D*H)

1195*720*1950mm

1495*720*1950mm

1795*720*1950mm

HEPA filter specifications and quantity

955*554*50mm*1pc

1290*554*50mm*1pc

1590*554*50mm*1pc

Fluorescent/UV lamp specifications and quantity

20W*1PC/20W*1PC

30W*1PC/30W*1PC

30W*PC/30W*1PC

 

(2)All steel class II A2/B2 series

 

Model

BSC-1000IIA2/BSC-1000IIB2

BSC-1200IIA2/BSC-1200IIB2

BSC-1500IIA2/BSC-1500IIB2

 

 

 

 

Picture

Clean level

Grade 100(209 E U.S. Federal)

Grade 100(209 E U.S. Federal)

Grade 100(209 E U.S. Federal)

Number of bacteria

≤0.5per utensil.hour(90mm utensil)

≤0.5per utensil.hour(90mm utensil)

≤0.5per utensil.hour(90mm utensil)

Average wind speed

Inside the door

0.38m/s±10%

0.38m/s±10%

0.38m/s±10%

Middle

0.26m/s±10%

0.26m/s±10%

0.26m/s±10%

Inside

0.27m/s±10%

0.27m/s±10%

0.27m/s±10%

Front suction wind speed

0.55m/s±10%

0.55m/s±10%

0.55m/s±10%

Noise

≤58dB(A)

≤58dB(A)

≤58dB(A)

Working area dimension(W*D*H)

800*550*600mm

1000*550*600mm

1300*550*600mm

Overall dimension(W*D*H)

1000*800*2100mm

1200*800*2100mm

1500*800*2100mm

 

 

Product Display

 

 

Why Choose Us?

1. On-time Delivery

  Our on-time delivery rate is 100%. Delivery time is usually 7-15 working days after payment.

 

2. Rich Export Experience

  Drawell is founded in 1999, and has more than 20 years of exporting experience. We have a professional sales team of around 30 peoples.

Our main markets are South Africa, Middle East, Southeast Asia, Europe, etc. So far, we have established business relationships with more than 100 countries.

 

3. Quick Service

  For the before-order stage, our professional sales team will respond to your inquiry within 24 hours whether it is on working days or not.

  For the order-running process, we will keep track of your order. You don’t have to worry about the quality or production time.

  For the after-sales stage, our technical guidance is free and ready forever. If you have any problems, our after-sales team and engineers will help you solve it, and you will get an answer within 24 hours.

 

 

Order Process of Vacuum Drying Oven

 


Payment

● More Payment terms could be provided (T/T, PAYPAL, WESTERN UNION)

 

 

Logistics 

 

 

FAQ

1. Are you a factory or trading company?

- We are a factory.

2. What is the MOQ?

- Normally, MOQ is 1 piece

- If there is no stock, the general MOQ are in a big difference between different products. But the quantity still can be negotiated.

3. Can we ask for a sample from your company?

- Sample is available, but we do not provide a free sample.

4. Do you provide OEM service?

- OEM service is available with the customer's brand.

5. Which payment can be acceptable?

- We accept the payment by T/T, Paypal, Western Union, etc.

6. How about your delivery time?

- Generally, it will take 7-15 working days after receiving your advance payment. Depend on the quantity.

7. What after-sales service do you provide?

- We could provide Online instruction; Real-time support by video call or voice chat; During warranty time, we can send product accessories when you need them for free; Technical guidance is free and ready forever. 

8. How long is the warranty?

- 1 year. it can be negotiated if you need an extended warranty.

9. If you have other questions, you can contact us through:

- Email: sales08@drawell.com.cn

- Tel: 008613320353102

CONTACT US

  • weIcome to contact us, we wiIl do our best to help you !