Handheld XRF Metal/Alloy/Stainless Steel Analyzer DW-EX 5000
DW-EX5000 handheld XRF adopts Photoelectron, microelectronics, semiconductor, computer, and many other technologies and develops the new generation of handheld XRF with Independent Property Rights. DW-EX5000 handheld alloy analyzer uses a large-screen, high-resolution LCD, and the new digital signal processor. The minimum detection limits make its performance as great as the desktop. With its small size and lightweight, DW-EX5000 is portable for testing and suitable for analyzing different kinds of alloy.
Application Field of DW-EX5000 handheld XRF
- Boiler pressure vessel
- Iron and steel smelting
- Waste metal recycling
- Machinery manufacturing and processing
- Boiler pressure vessel
- Aerospace industry
- Shipbuilding
- ……

DW-EX5000 can make accurate and nondestructive detection on a variety of precious metal alloys, low alloy steel, stainless steel, tool steel, chrome/molybdenum steel, nickel alloys, cobalt alloys, nickel / cobalt-resistant alloys, titanium, copper alloy, bronze, zinc alloy, tungsten alloy, etc. Knowing the materials composition and alloy kind in one second. Rapid detection of aluminum and magnesium alloy grades is possible and it allows to make reliable identification and confirmation of the material (PMI) and precisely controls the quality of the materials.
Reliable identification of materials
In the process of alloy materials production and machinery manufacturing and processing, elements detection can’t work without the identification of materials. DW-EX5000 professional and nondestructive detection can effectively prevent the mix of raw material and avoid unnecessary loss.
Quality control in industrial production
DW-EX5000 professional and nondestructive detection can be used for quality control and management in the manufacturing process of steel smelting, boiler industry, and other high-temperature and high-pressure industries to ensure the quality of the materials; identification of alloy composition in shipbuilding, aerospace, and other high-tech industries in order to ensure product quality and safety; identification on the quality of the spare parts in electric power plants and other industries related to people’s livelihood to guarantee the equipment safety.

Waste metals recycling and reuse
In the waste metal recycling and reuse industry, EXPLORER 5000 can make on-site detection and rapid classification of scrap metals; recycle overstocked steel in the warehouse; classify metals in the salvage station; recycle the turning scraps and cuttings. It s a powerful tool to make metal and steel identification in the waste metals recycling industry.
Features of DW-EX5000 handheld XRF
- Easier Operating

- Light & small, ergonomic handle design, equipped with a special instrument case, easier to grasp and more convenient to use in the field.
- 5-inch high-definition screen with 360-degree rotation, multiple points operating, can display clearly at any lights.
- Integrated design of Seal type, with waterproof and dustproof function, can be used continuously in harsh environments.
- Directly measure and analyze the surface of samples and goods. Can do a quick measurement by its handheld benefit and accurately test samples for a long time by its test block.
2. Better Performance

- Rapid non-destructive detection and quick measurement by aiming, to report results within one second. Comparable to the bench-top XRF, fast and accurate.
- Simultaneous detection of Ti)V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, Zr, Nb, Mo, Ru, Rh, Pd, Ag, In, Sn, Sb, Hf, Ta, W, Re, Pt, Au, Pb, Bi, Mg, Al, Si, P, S, and it can add customized elements.
- The instrument can run without helium by the ultra near optical path design and can detect the light elements from the beginning of Mg that fully meets the needs of specific users.
3. Strong Battery
- A large lithium battery at 27000mAh could be a selected configuration; the battery duration working time is up to three days, and it is equipped with a communicator and car charger to ensure power supply.
- A Built-in memory battery can continue to replace the battery power.
4. Higher Configuration

- Four core parts which are a Miniature X-ray tube, a Fast-SDD detector (the world’s best detector), a digital signal processor, and a micro multichannel intelligent analysis module, can achieve an accuracy as good as bench-tops.
- Large data storage is by ultra-high frequency memory and mass storage space. Our new independent research and development Digital multichannel technology ensure effective mining spectral counts per second is up to 500K cps.
- The collimation filter system, its combination can reach the limit of 12 groups, to meet the testing requirements of different customers.
- Built-in 500W pixels high definition camera can observe the sample’s resting position at any time that making the measurement more accurate.
5. Safer Protection

•Intelligent-tricolor-early-warning-system: 360 degrees without dead angle display by LED three-color lamp design. Instrument status is shown in different colors: Green light means power on; Red flushing means testing; Yellow flushing means fault.
•Triple safety protection function:
a: Automatic induction, the instrument does not work without sample, no leakage radiation.
b: Thicken – preventing – testing – wall can effectively prevent the scattering.
c: Safety – protection – cover can prevent the surrounding light matrix scattering.
• Security-linkage-locking device protects your security; it can guard the final checkpoint if the software is unable to control the instrument turned off.
6. More Intelligent Software
• DW-EX5000 alloy analyzer is equipped with professional application software, specifically for the alloy industry; the feature is intelligent, high sensitivity, short testing time, and easy operation.
• Brand new knowledge-ware is one key operation with dual-mode design
a.User mode uses for recognizing categories of the sample by one key operation;
b.Expert mode uses for increasing the elements and increasing the specific in-depth analysis of the operation curve.
• Internal intensity correction method can correct deviation caused by an uneven sample of different geometries, densities, and structures.
Specifications of DW-EX5000 handheld XRF
Analytical Method | Energy dispersive X ray fluorescence analytical Method |
Elements Measuring Range | Atomic number from 12 to 92 |
[elements from magnesium (Mg) to uranium (U)] can be measured | |
Simultaneous detector elements | Simultaneous analyze 40 elements |
Microcomputer system | Customized system; CPU: 1G ; |
System memory: 1G ; extended stored maximum support 32G ; | |
Standard 4G for mass storage data | |
The content range | ppm ~ 99.99% |
The detection time | 1〜60 seconds (one second report results) |
A built-in system | GPS, WIFI, Bluetooth |
Power Supply | Rechargeable lithium battery, standard is 9000mAh, sustainable work up to 12 hours; optional is 27000mAh superbattery with wide voltage 110V ~ 220V universal adapter for recharging power supply |
Detection Objective | Solid, liquid, powder |
Detector | SDD detector or Fast-SDD detector (optional) |
Detector resolution | Minimum can reach 128eV |
The excitation source | 50KV/200uA- silver target end window integrated miniature X-ray tube and high voltage power supply |
Collimator and filter | Collimator diameters are 4.0mm and 2.0mm, 6 kinds of filters with automatic switching functions |
Video system | 500W pixel high resolution camera |
Display screen | Brand new 5 inch semi-reflecting and semi-transmitting LCD touch screen, its resolution is 1080*720. |
Detection limit | The minimum detection limits at 1 ~ 500 ppm |
Safety | Multiple safety protection, no tests, no radiation, radiation levels at work are far below the international safety standards, and has no sample telemetry, automatic -turn -off X-Ray tube function. Standard radiation shields, thickened instrument’s alloy testing wally test instrument |
Specialty | Ore Special edition of ore’s analytical software, and intellectualized one key testing. |
Convenience of application | No need to select curves, intellectualized one- key-selecting will select the best matching curve |
Data transmission | Digital multi-channel technology, SPI data transmission, quick analysis, the high count rate; waterproof mini USB, and can be connected with a desktop computer |
Operating ambient humidity | ≤90% |
Operating environmental temperature | -20°C~+50°C |
Instrument dimension | 244mm ( Length) x 90mm (Width) x330mm ( Height) |
Instrument weight | 1.7Kg |
Intelligent warning signalslndicator system | Green light means power on, red flushing means testing and yellow flushing means the errors |
Accessories | Three-miIitary-protection-box is compression, waterproof and shock absorption. |
Two lithium battery and charger, PDA accessories, radiation shield. | |
Universal charger and car charger, 4G SD memory card and card reader | |
Optional accessories: the large battery, seat type test support, Bluetooth printer, mill, manual pressure machine, and different meshes of sieves |
Exclusive Accessories

An Introduction to Precious Metals Analysis
Precious metals refer to the 8 metal elements Au, Ag and Ru, Rh, Pd, Os, Ir, and Pt in the Pt family. Most of these metals have beautiful colors. They are normally unreactive as they have strong resistance to chemicals. They are usually made into jewelry or souvenirs and have wide industrial applications.
DW-EX5000 can test the grades and purity of the precious metals, identify grades of gemstones, and conduct routine physical, compositional, and structural analyses of jewelry.
DW-EX5000 tests precious metal fineness for gold, silver, platinum, palladium, etc. in accordance with National Standard GB 11887 Jewelry一Fineness of Precious Metal Alloys and Designation and GB/T 18043 Precious Metals Jewelries Content Non-destructive Test Method X-ray Fluorescence Spectrometry.
