Benchtop High Speed Centrifuge TG16-WS/TG18-WS

TG16-WS/TG18-WS Benchtop High Speed Centrifuge is useful for routine application in biotechnology, PCR, life science and clinical labs, etc. This is suitable for routine sample analysis in Medical, Hospital, and Institutional laboratories. With a wide choice of rotor heads and adapters, this unit is truly versatile.

TG-series--LCD-白底
LCD display
TG-series-Digital-白底
Digital display

Features of TG16-WS/TG18-WS Benchtop High-Speed Centrifuge

  1. Reliable drive system, with low noise level and running stable.
  2. Protection for door lid, over-speed, and imbalance.
  3. Easy operation, and easy to load and unload rotors.
  4. Stainless steel chamber and full metal structure.
  5. With manual emergency lid release for unexpected power interruption.
  6. Brush-less induction motor with frequency drive ensures a gentle start.

Technical Parameters of TG16-WS/TG18-WS

TG16-WS Benchtop High-Speed Centrifuge

ModelTG16-WSSpeed  Accuracy±50r/min
Max Speed16000r/minTimer Range0~99min
Max RCF21800xgMotorBrushless Converter Motor
DisplayLCD /Digital displayNoise≤60dB(A)
Max Capacity4 x100mlPower SupplyAC220v&110V 50Hz 5A
Weight30kgDimension410x352x310mm(L*W*H)

Rotors of TG16-WS Benchtop High-Speed Centrifuge

图片1 17No.1

Max Speed:16000r/min

Capacity:12×1.5/2.2ml AR

Max RCF:17800xg

图片6 3No.2

Max Speed:13000r/min

Capacity:8×5ml AR

Max RCF:11400xg

图片3 9No.3

Max Speed:12000r/min

Capacity:12×10/15ml AR

Max RCF:14800xg

图片2 14No.4

Max Speed:15000r/min

Capacity:24×1.5/2.2ml AR

Max RCF:21800xg

图片5 4No.5

Max Speed:13500r/min

Capacity:48×0.5/1.5ml AR

Max RCF:14800xg

图片1 17No.6

Max Speed:13500r/min

Capacity:48×1.5/2.2ml AR

Max RCF:17600xg

图片7 副本No.7

Max Speed:11000r/min

Capacity:6×50/30ml AR

Max RCF:12000xg

图片8 2No.8

Max Speed:10000r/min

Capacity:4×100ml AR

Max RCF:9800xg

图片9 2No.9

Max Speed:4000r/min

Capacity:2×2×48 holes

Max RCF:1400xg

图片10 2No.10

Max Speed:8000r/min

Capacity:8×50ml AR

Max RCF:9800xg

Rotor — Note: Rotors can customize made

TG18-WS Benchtop High-Speed Centrifuge

ModelTG18-WS
Max Speed18000r/min
Max RCF23200xg
DisplayLCD /Digital display
Max Capacity4 x100ml
Weight30kg
Speed  Accuracy±50r/min
Timer Range0~99min
MotorBrushless Converter Motor
Noise≤60dB(A)
Power SupplyAC220v&110V 50Hz 5A
Dimension410x352x310mm(L*W*H)

Rotor of TG18-WS Benchtop High-Speed Centrifuge

图片4 8No.1

Max Speed:18000r/min

Capacity:12×1.5/2.2ml AR

Max RCF:23200xg

图片6 副本No.2

Max Speed:14000r/min

Capacity:8/10×5ml AR

Max RCF:14800xg

图片3 9No.3

Max Speed:13000r/min

Capacity:12×10/15ml AR

Max RCF:17760xg

图片2 14No.4

Max Speed:15000r/min

Capacity:24×1.5/2.2ml AR

Max RCF:21800xg

图片5 4No.5

Max Speed:14000r/min

Capacity:36×0.5/1.5ml AR

Max RCF:17760xg

图片1 17No.6

Max Speed:14000r/min

Capacity:48×1.5/2.2ml AR

Max RCF:18200xg

图片7 副本No.7

Max Speed:12000r/min

Capacity:6×50/30ml AR

Max RCF:15140xg

图片8 2No.8

 

Max Speed:10000r/min

Capacity:4×100ml AR

Max RCF:9800xg

图片9 2No.9

Max Speed:4000r/min

Capacity:2×2×48 holes

Max RCF:1400xg

图片10 2No.10

Max Speed:8000r/min

Capacity:8×50ml AR

Max RCF:9800xg

Other Benchtop High Speed Centrifuge