This VS2000V veterinary vital signs monitor is intended to be used in special procedure labs and other areas of a veterinary hospital or clinic where veterinary monitoring systems are needed. The monitor package includes 3-lead or 5-lead electrocardiography (ECG), noninvasive blood pressure (NIBP), temperature (TEMP) and pulse oximetry (SpO2).The device permits patient monitoring with adjustable alarm limits as well as visible and audible alarm signals. The monitor provides fast, reliable measurements for patientsranging from cats to horses when using the appropriate accessories.

Features of VS2000V Monitor:
- 7″ high resolution color LCD display with adjustable brightness.
- Lightweight and portable, easy for veterinarians to carry out.
- Built-in rechargeable lithium battery for long term continuous operation.
- 3 leads and 5 leads ECG cable are selectable.
- Variety of NIBP Cuffs for different size animals.
- Expanded heart rate values and Veterinary specific SpO2 sensors to accommodate a variety of species.
- Widely used in pet hospitals and animal clinics etc.
- Two-year warranty.

SPECIFICATIONS of VS2000V Monitor
Enclosure
Weight |
2.05kg (4.52 lb), including 1 battery |
Dimensions |
324mm Wx 129mm Hx 183 mmD (12.76in. W x 5.08in. H x 7.20in. D) |
Display |
|
Screen size |
177.8 mm ( 7in.), measured diagonally |
Screen type |
TFT LCD, white LED backlight, viewing cone of 60°and optimal viewing distance of 1.5 meter |
Resolution |
800 x480 pixels |
Alarms |
|
Categories |
Patient status and system status |
Priorities |
Low, medium, and high |
Notification |
Audible and visual |
Setting |
Full storage, low battery and sensor off |
Alarm volume level |
45 to 85 decibels |
Alarm system delay |
<10 seconds |
SpO2
Aturation range |
1% to 100% |
Resolution |
1% |
Accuracy |
70-100% (±2%), <70% undefined |
Display sweep speed |
10.00 mm/sec |
Pulse Rate
Aturation range |
25bpm to350bpm |
Resolution |
1bpm |
Accuracy |
±2bpm/±2% take maximum |
ECG
Aturation range |
25bpm to350bpm |
Leads |
I,II,III,V,aVR,aVL or aVL |
Accuracy |
±2bpm/±2% take maximum |
Display gain |
X1/4, X1/2, X1, X2, X4 |
Resolution |
1bpm |
Display sweep speed |
6.25, 12.5, 25, 50mm/sec |
NIBP
Method |
Oscillometric |
Measurement Time |
30-50s typical, 180s maximum |
Aturation Range |
0-300mmHg |
AUTO Interval Times |
2, 3, 5, 10, 30 min, or 1, 2h |
Accuracy |
Based on ANSI/AAMI SP10:1992 and 2002 Standards |
RESP
Aturation range |
0-130rpm |
Resolution |
1rpm |
Accuracy |
±1 pm |
TEMP
Aturation range |
0-50°C |
Resolution |
0.1°C |
Accuracy |
±0.2°C |
ETCO2 (Optional)
Mode |
Sidestream |
Resolution |
0.lmmHg |
Aturation Range |
0-150mmHg |
Flow rate |
50ml/min ±10ml/min |
Accuracy |
0-40mmHg ±2mmHg 41-150mmHg ±10% of reading |
Electrical
Battery |
Four new lithium batteries with 4,400mAh will typically provide 4.5 hours of monitoring with no external communication, no audible alarm sound, and at an ambient temperature of 25°C |
Type |
Lithium Batteries, 4,400mAh, DC 11.1V |
Voltage |
AC 100-240V, 50-60Hz, 80VA |
Environmental
Transport and Storage |
Operating Conditions |
|
Temperature |
-40°C to 75°C (-40°F to 167°F) |
0°C to 50°C (32°F to 122°F) |
Altitude |
-500 to 5,000m (-1,640 to 16,404 ft.) |
|
Relative humidity |
15% to 95% noncondensing |
Trend
Tabular |
|
Memory |
Saves a total of 120 hours of data events; saves date and time, alarm conditions, measurements |
Tabular format |
One table for all parameters |
Configuration
Standard |
SpO2+ECG+NIBP+RESP+TEMP |
Optional |
SpO2, SpO2+NIBP, SpO2+NIBP+ECG, SpO2+NIBP+TEMP SpO2+ECG+NIBP+RESP+TEMP+ETCO2, etc. Lithium Battery, Trolley, Brace, IPMS8600 Central monitoring system |