Ultrasonic Cleaner
The Ultrasonic cleaner is an advanced cleaning device designed to remove contaminants from delicate instruments and components using high-frequency ultrasonic waves. It effectively cleans surfaces without causing damage, making it ideal for laboratory equipment, medical tools, jewelry, and electronic parts, featuring adjustable cleaning time, temperature control, and durable construction.
Application Areas of Ultrasonic Cleaner
Drawell Ultrasonic cleaners are used to clean many different types of objects, including jewelry, scientific samples, lenses, and other optical parts, watches, dental and surgical instruments, tools, coins, fountain pens, golf clubs, fishing reels, window blinds, firearm components, car fuel injectors, musical instruments, gramophone records, industrial machine parts, and electronic equipment. They are used in many jewelry workshops, watchmakers’ establishments, electronic repair workshops, and scientific labs.

How Does Ultrasonic Cleaner Work
- Cavitation: Ultrasonic waves penetrate the liquid with compression force and sharp high frequency, generating strong impact force, thereby stripping dirt from the surface of the object being cleaned.
- Straight-through flow: Straight-through flow stirs the dirt on the surface of the object being cleaned, and the cleaning liquid on the surface also generates convection, which accelerates the dissolution rate and has a great transport effect on the dirt.
- Acceleration: For high-frequency ultrasonic cleaning machines, the liquid particles are mainly accelerated by the impact of the particles under the action of ultrasound to perform ultra-precision cleaning on the dirt.
Differences Among Ultrasonic Cleaning Machine
D Series
- Digital display
- Stainless steel
- 1-600 minutes adjustable
DT Series
- LCD display
- Stainless steel
- 1-99 minutes adjustable
DTD Series
- LED display
- Stainless steel
- 1-999 minutes adjustable
DTS Series
- Digital display
- Stainless steel
- 1-999 minutes adjustable
- Dual-frequency
DWL Series
- LCD display
- Stainless steel
- 1-999 minutes adjustable
- Constant Temperature
DTY Series
- LCD display
- Stainless steel
- 1-999 minutes adjustable
- Multi-frequency
Specifications of Ultrasonic Cleaner
(1) D Series Ultrasonic Cleaning Machine
Features:
- Digital display and setting ultrasonic cleaning time;
- Display working countdown time;
- Timing range: 1-600 minutes adjustable;
- Equipped with a special stainless steel basket, reduce sound cover;
- The shell and cover are made of stainless steel;
- The equipment is controlled by a single-chip controller;
- The latest working parameters can be stored in memory after power-off.
Model | DW-80 | DW-120D | DW-5200D | DW25-12D |
Picture | | | | |
Inner Tank (L/W/H ( mm)) | 155×140×100 | 240×140×100 | 300×240v150 | 500×300×150 |
Volume (L) | 2 | 3 | 10 | 22.5 |
Frequency(KHz) | 40 | 40 | 40 | 40 |
Power (W) | 80 | 120 | 200 | 500 |
Adjustable Time (min) | 1-120 | 1-600 | 1-600 | 1-600 |
Drainage | / | / | √ | √ |
Net Weight (Kg) | 2.2 | 4.5 | 6.8 | 13 |
Packing Size (mm) | 240×230×300 | 325×230×300 | 450×325×375 | 640×395×375 |
(2) DT Series Ultrasonic Cleaning Machine
Features:
- Digital display and setting ultrasonic cleaning time;
- Display working countdown time;
- Display the actual temperature of the cleaning tank;
- Temperature setting range: Ambient temperature–80℃;
- Timing range: 1-99 minutes adjustable;
- Equipped with a special stainless steel basket, reduce sound cover;
- The shell and cover are made of stainless steel;
- The equipment is controlled by a single-chip controller;
- The latest working parameters can be stored in memory after power-off.
Model | DW-100DT | DW-5200DT | DW25-12DT | DW-1200DT |
Picture | | | | |
Inner Tank (L/W/H ( mm)) | 300×150×100 | 300x240x150 | 500x300x150 | 600x400x300 |
Volume (L) | 4.5 | 10 | 22.5 | 70 |
Frequency(KHz) | 40 | 40 | 40 | 28 |
Power (W) | 100 | 240 | 720 | 1200 |
Heating power(W) | 200 | 800 | 1000 | 4000 |
Adjustable temperature(℃) | RT-80 | RT-80 | RT-80 | RT-80 |
Adjustable Time (min) | 1-99 | 1-99 | 1-99 | 1-99 |
Net Rack | Yes | Yes | Yes | Yes |
Sound reduce cover | Yes | Yes | Yes | Yes |
Drainage | / | Yes | Yes | Yes |
(3) DTD Series Ultrasonic Cleaning Machine
Features:
- Large-screen LCD display;
- Display the parameters setting menu;
- Adjustable power: 40%-100%;
- Digital setting ultrasonic cleaning time;
- Working time countdown display;
- Display the actual temperature of the cleaning tank;
- Temperature setting Range: room temperature–80℃;
- Timing Range: 1-999minutes adjustable;
- Equipped with a special stainless steel basket, reduce sound cover;
- The shell and cover are made of stainless steel;
- The equipment is controlled by a single-chip controller;
- The latest working parameters can be stored in memory after power-off.
Model | DW-3200DTD | DW-5200DTD | DW-4200DTD | DW25-12DTD |
Picture | | | | |
Inner Tank (L/W/H ( mm)) | 300x155x150 | 300x240x150 | 300x240x200 | 500x300x150 |
Volume (L) | 6 | 10 | 14.4 | 22.5 |
Frequency(KHz) | 40 | 40 | 40 | 28 |
Power (W) | 180 | 240 | 480 | 600 |
Power Adjustable (%) | 40-100 | 40-100 | 40-100 | 40-100 |
Heating power(W) | 300 | 500 | 500 | 800 |
Adjustable temperature(℃) | RT-80 | RT-80 | RT-80 | RT-80 |
Adjustable Time (min) | 1-999 | 1-999 | 1-999 | 1-999 |
Net Rack | Yes | Yes | Yes | Yes |
Sound reduce cover | Yes | Yes | Yes | Yes |
Drainage | / | Yes | Yes | Yes |
(4) DTS Series of Dual-frequency Ultrasonic Cleaning Machine
Features:
- Interchangeable use of two kinds of frequencies: 25KHz, 40KHz;
- Digital display and setting ultrasonic cleaning time;
- Display woking countdown time;
- Display the actual temperature of the cleaning tank;
- Temperature setting range: Ambient temperature — 80℃;
- Timing range: 1-999minutes adjustable;
- Equipped with a special stainless steel basket, reduce sound cover;
- The shell and cover are made of stainless steel;
- The equipment is controlled by a single-chip controller;
- The latest working parameters can be stored in memory after power-off.
Model | DW-3200DTS | DW-5200DTS | DW-4200DTS | DW25-12DTS |
Picture | | | | |
Inner Tank (L/W/H ( mm)) | 300x155x150 | 300x240x150 | 300x240x200 | 500x300x150 |
Volume (L) | 6 | 10 | 14.4 | 22.5 |
Frequency(KHz) | 25/40 | 25/40 | 25/40 | 25/28 |
Power (W) | 180 | 240 | 480 | 600 |
Power Adjustable (%) | 40-100 | 40-100 | 40-100 | 40-100 |
Heating power(W) | 400 | 800 | 800 | 1000 |
Adjustable temperature(℃) | RT-80 | RT-80 | RT-80 | RT-80 |
Adjustable Time (min) | 1-999 | 1-999 | 1-999 | 1-999 |
Net Rack | Yes | Yes | Yes | Yes |
Sound reduce cover | Yes | Yes | Yes | Yes |
Drainage | / | Yes | Yes | Yes |
(5) DTY Multi-frequency Ultrasonic Cleaning Machine (25KHz,33KHz,40KHz,59KHz)
Features:
- Background light LCD screen;
- Microcomputer memory setting parameters;
- The ultrasonic working time is set up independently: (0-99 minutes adjustable);
- Multi-frequency conversion: 25KHz, 28KHz, 40KHz, 59KHz;
- Display woking countdown time;
- Display the actual temperature of the cleaning tank;
- Temperature setting range: Ambient Temperature — 80℃;
- Timing range: 0-999 minutes adjustable;
- Equipped with a special stainless steel basket, reduction sound cover;
- The shell and cover are made of stainless steel;
- The equipment is controlled by the single-chip controller;
- With drainage function.
Model | DW-300DTY | DW-400DTY | DW-500DTY | DW-600DTY |
Picture | | | | |
Inner Tank (L/W/H ( mm)) | 300x240x150 | 300x240x200 | 500x300x150 | 500x300x200 |
Volume (L) | 10 | 15 | 22.5 | 30 |
Frequency(KHz) | 25KHz,33KHz,40KHz, 59KHz | 25KHz,33KHz,40KHz, 59KHz | 25KHz,33KHz,40KHz, 59KHz | 25KHz,33KHz,40KHz, 59KHz |
Power (W) | 360 | 480 | 600 | 840 |
Heating power(W) | 800 | 800 | 1000 | 3000 |
Adjustable temperature(℃) | RT-80 | RT-80 | RT-80 | RT-80 |
Adjustable Time (min) | 1-999 | 1-999 | 1-999 | 1-999 |
Net Rack | Yes | Yes | Yes | Yes |
Sound reduce cover | Yes | Yes | Yes | Yes |
Drainage | Yes | Yes | Yes | Yes |
Ultrasonic Cleaning Machine Display
Customer Feedback of Ultrasonic Cleaning Machine
How to Operate Ultrasonic Cleaner?
1. Preparation
Check whether the equipment is intact and has no damage or leakage. Select appropriate cleaning agent according to the nature of the items to be cleaned Completely immerse the items to be cleaned in the cleaning solution.
2. Operation
Turn on machine, adjust the appropriate cleaning time and power. According to needs, adjust the temperature of the cleaning solution accelerate the cleaning effect
3. End and follow-up processing
Take out the cleaned items and rinse them with clean water to remove the remaining cleaning agent and dirt. Clean the cleaning tank and cleaning liquid for next use.
Composition of Ultrasonic Cleaner
- The ultrasonic cleaner is is mainly composed of ultrasonic cleaning tank and ultrasonic generator.
- The ultrasonic cleaning tank is made of strong, elastic and corrosion-resistant stainless steel.
- The ultrasonic generator generates high-frequency resonance, so that the solvent in the cleaning tank is affected by ultrasonic waves to clean the dirt.