iTGD-16MC iTGD-18MC iTGD-20MC Intelligent High & Low Speed Refrigerated Centrifuge
iTGD-16/18/20MC intelligent high & low speed refrigerated centrifuge is available with a wide range of rotors, and exceptional versatility. It has fast speed up and speeds down functions and LCD touch display. iTGD series centrifuge widely use in laboratory, medical, biological, research, molecular biology etc.
Features of Refrigerated Centrifuge iTGD-16/18/20MC
- Microprocessor control, speed control by frequency-conversion and CFC compressor.Maintenance free Frequency-conversion motor without carbon dust pollution.
- Advanced door lid control system can both electric control open and close door lid, also equipped with emergency lid lock release to avoid power off unexpected.
- 10 programs can be stored, quickly recall the last used program.
- Automatic rotor identification to avoid over speed running by mistake operate.
- Easy operation, 7 inches LCD touch panel, shows all parameters in screen.
- With Emergency lid lock release, in case of power off.
- Error minder for wrong operate or problem.
Technical Parameters of Refrigerated Centrifuge iTGD-16/18/20MC
Model | iTGD-16MC | iTGD-18MC | iTGD-20MC | Speed Accuracy | ±10r/min |
Max Speed | 16500r/min | 18500r/min | 20500r/min | Timer Range | 1s~99h59mins 59s |
Max RCF | 21800xg | 23500xg | 28200xg | Temp Range | -20℃~﹢40℃ |
Display | LCD Touch display | Max Capacity | 4×250ml | ||
Noise | ≤60dB(A) | Power Supply | AC220v&110V 50Hz 10A | ||
Weight | 85kg | Dimension | 720x500x420mm |
Rotors of Refrigerated Centrifuge iTGD-16/18/20MC
No.1 AR | ![]() |
Max Speed:20500r/min | No.2 AR | ![]() |
Max Speed:16000r/min |
Capacity:12×1.5/2ml | Capacity:8×5ml | ||||
Max RCF:28200xg | Max RCF:3020xg | ||||
No.3 AR | ![]() |
Max Speed:14000r/min | No.4 AR | ![]() |
Max Speed:15000r/min |
Capacity:12×10ml | Capacity:24×1.5/2ml | ||||
Max RCF:23120xg | Max RCF:21800xg | ||||
No.5 SR | ![]() |
Max Speed:14000r/min | No.6 AR | ![]() |
Max Speed:14000r/min |
Capacity:48×1.5ml | Capacity:36×1.5/2ml | ||||
Max RCF:17600xg | Max RCF:18200xg | ||||
No.7 AR | ![]() |
Max Speed:13000r/min | No.8 AR | ![]() |
Max Speed:10000r/min |
Capacity:6×50ml | Capacity:4×100ml | ||||
Max RCF:16760xg | Max RCF:9800xg | ||||
No.9 SR | ![]() |
Max Speed:4000r/min | No.10 AR | ![]() |
Max Speed:8000r/min |
Capacity:4×250ml | Capacity:6x100ml | ||||
Max RCF:3300xg | Max RCF:9800xg | ||||
No.11 AR | ![]() |
Max Speed:13000r/min | No.12 AR | ![]() |
Max Speed:12000r/min |
Capacity:6x30ml | Capacity:12x15ml | ||||
Max RCF:17000xg | Max RCF:15100xg |