
Features of EP Adjustable Autoclavable Pipette
- Professional design. Unique shape. Comfortable handle.
- In accordance with Human engineering.
- Special metal materials to ensure the durability, accuracy and stability, and to guarantee no maintenance in one year.
- All-around lock catch to let operator lock range, making adjustable pipette be used as fixed pipettes with various range.
- Operators can calibrate pipette independently by tool in each package.
Model No. | Volume (µL) | Increment (µL) | Rel. % | Abs (µL) | Rel. CV% | Abs SD (µL) |
EP2 | 0.2 | 0.002 | 12.0 | 0.024 | 6.00 | 0.012 |
1 | 2.7 | 0.027 | 1.30 | 0.013 | ||
2 | 1.5 | 0.030 | 0.70 | 0.014 | ||
EP10 | 1 | 0.02 | 2.5 | 0.025 | 1.20 | 0.012 |
5 | 1.5 | 0.075 | 0.60 | 0.030 | ||
10 | 1.0 | 0.100 | 0.40 | 0.040 | ||
EP20 | 2 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
10 | 1.5 | 0.15 | 0.50 | 0.050 | ||
20 | 1.0 | 0.20 | 0.30 | 0.060 | ||
EP50 | 5 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
25 | 1.5 | 0.15 | 0.50 | 0.050 | ||
50 | 1.0 | 0.20 | 0.30 | 0.060 | ||
EP100 | 10 | 0.2 | 3.5 | 0.35 | 1.00 | 0.10 |
50 | 0.8 | 0.40 | 0.24 | 0.120 | ||
100 | 0.8 | 0.80 | 0.15 | 0.150 | ||
EP200 | 20 | 0.2 | 2.5 | 0.5 | 1.00 | 0.200 |
100 | 0.8 | 0.8 | 0.25 | 0.250 | ||
200 | 0.8 | 1.60 | 0.15 | 0.300 | ||
EP300 | 30 | 0.2 | 2.5 | 0.5 | 1.00 | 0.02 |
150 | 0.8 | 0.8 | 0.25 | 0.25 | ||
300 | 0.8 | 1.60 | 0.15 | 0.30 | ||
EP1000 | 100 | 2.0 | 3.0 | 3.0 | 0.60 | 0.600 |
500 | 0.8 | 4.0 | 0.20 | 1.000 | ||
1000 | 0.8 | 8.0 | 0.15 | 1.5 | ||
EP5000 | 500 | 5.0 | 2.4 | 12.0 | 0.60 | 3.0 |
2500 | 0.6 | 15.0 | 0.20 | 5.0 | ||
5000 | 0.6 | 18.0 | 0.16 | 8.0 |
Features of EPP Adjustable Autoclavable Pipette
- Fully autoclavable. ( 121℃ for 20 minutes )
- Enhanced UV resistance.
- Easy digital volume setting.
- Easy and convenient single hand locking lever.
- Eight sizes to cover a wide volume range. ( 0.1μL – 10mL )
- PTFE ( Fluorine resin ) is used in the airtight chamber of the instrument, so the instrument keeps its air tightness and precise reproducibility for long hours.
- Filtered Nozzles are used for volume models larger than 1000μL.
- Tip ejector allows tip ejections without touching the tip.
- Tip ejector is made of plastic to avoid damaging glass tubes.
Model No. | Volume (L) | Increment (L) | Rel.% | -% Abs L | Rel.CV%・CV% | Abs SD L |
EPP2 | 0.2 | 0.002 | 12.0 | 0.024 | 6.00 | 0.012 |
1 | 2.7 | 0.027 | 1.30 | 0.013 | ||
2 | 1.5 | 0.030 | 0.70 | 0.014 | ||
EPP10 | 1 | 0.02 | 2.5 | 0.025 | 1.20 | 0.012 |
5 | 1.5 | 0.075 | 0.60 | 0.030 | ||
10 | 1.0 | 0.100 | 0.40 | 0.040 | ||
EPP20 | 2 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
10 | 1.5 | 0.15 | 0.50 | 0.050 | ||
20 | 1.0 | 0.20 | 0.30 | 0.060 | ||
EPP50 | 5 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
25 | 1.5 | 0.15 | 0.50 | 0.050 | ||
50 | 1.0 | 0.20 | 0.30 | 0.060 | ||
EPP100 | 10 | 0.2 | 3.5 | 0.35 | 1.00 | 0.10 |
50 | 0.8 | 0.40 | 0.24 | 0.120 | ||
100 | 0.8 | 0.80 | 0.15 | 0.150 | ||
EPP200 | 20 | 0.2 | 2.5 | 0.5 | 1.00 | 0.200 |
100 | 0.8 | 0.8 | 0.25 | 0.250 | ||
200 | 0.8 | 1.60 | 0.15 | 0.300 | ||
EPP300 | 30 | 0.2 | 2.5 | 0.5 | 1.00 | 0.02 |
150 | 0.8 | 0.8 | 0.25 | 0.25 | ||
300 | 0.8 | 1.60 | 0.15 | 0.30 | ||
EPP000 | 100 | 2.0 | 3.0 | 3.0 | 0.60 | 0.600 |
500 | 0.8 | 4.0 | 0.20 | 1.000 | ||
1000 | 0.8 | 8.0 | 0.15 | 1.5 | ||
EPP5000 | 500 | 2.0 | 2.4 | 12.0 | 0.60 | 3.0 |
2500 | 0.6 | 15.0 | 0.20 | 5.0 | ||
5000 | 0.6 | 18.0 | 0.16 | 8.0 | ||
EPP10000 | 1000 | 2.0 | 3.0 | 3.0 | 0.60 | 0.6 |
5000 | 0.8 | 4.0 | 0.20 | 1.0 | ||
10000 | 0.8 | 8.0 | 0.15 | 1.5 |