DW-ES1000 Dry Bath Incubator (Heating lid)
The DW-ES1000 Dry Bath Incubator is a semi-conductor controlled heating & cooling instrument with automatic temperature control design. The flexible timer, constant temperature function and multi-point operation mode make it a unique and an ideal lab instrument.
Features of DW-ES1000 Dry Bath Incubator
- Instantly displays operation information on the LCD screen.
- Has combined temperature control system and block system. Each block has a built-in temperature sensor and heating/cooling unit, ensuring that temperature control is more accurate and the heating speed is much faster.
- Interchangeable, auto-recognized blocks.
- Adjustable heating lid. Temperature of heating lid can be controlled.
- Multi-point(max. 5 points) and Multi-cycle( Max.99 times) operation modes are provided.
- Auto restart in case of power failure.
- Over-heating protection device is included.
- Built-in temperature calibration function.
Parameters of DW-ES1000 Dry Bath Incubator
Model | DW-ES1000 | |
Block | DW-ES series | DW-ESC series |
Temp setting range | 0℃~100℃ | -10℃~100℃ |
Temp control range | RT+5℃~100℃ | RT.-25℃~100℃ |
Time range | 1sec ~ 99h59min/∞ | 1sec ~ 99h59min/∞ |
Temp accuracy | ≤±0.3℃@37℃ | ≤±0.3℃@37℃ |
Display accuracy | 0.1℃ | 0.1℃ |
Temp uniformity | ≤±0.3℃@37℃ | ≤±0.3℃@37℃ |
Heating time | ≤12min(from 25℃ to 100℃)* | ≤12min(from 25℃ to 100℃)* |
Cooling time 1 | — | ≤12min(from 100℃ to 25℃)* |
Cooling time 2 | — | ≤25min(from RT to RT-25℃)* |
Heating lid temp setting range | OFF~+10℃ | OFF~+10℃ |
Heating lid temp accuracy | ≤±0.5℃* | ≤±0.5℃* |
Heating lid heating time | ≤10min(from 25℃ to 100℃)* | ≤10min(from 25℃ to 100℃)* |
Storage at 4℃ | — | Yes * |
Multi-points running | Yes(Max 5points) | Yes(Max 5points) |
Multi-cycle | Yes(Max 99times) | Yes(Max 99times) |
Auto running | Yes | Yes |
Auto heating | Yes | Yes |
Auto resume to run | Yes | Yes |
Capacity | See optional block | See optional block |
Power | 150W | 150W |
Voltage | AC110 or AC220V/50-60HZ | AC110 or AC220V/50-60HZ |
Fuse | 250V 3A Ф5×20 | 250V 3A Ф5×20 |
Dimension(mm) | 300x200x210 | 300x200x210 |
Weight(kg) | 4.0 | 4.7 |
* Test condition:RT.25℃±2℃, block is 1.5mlx35, use mercurial thermometer, accuracy is ±0.1℃.
Optional Blocks
Type | Capacity | Temp. range |
ESC-01 | 35×2.0ml centrifuge tube | RT-25℃~100℃ |
ESC-02 | 35×1.5ml centrifuge tube | RT-25℃~100℃ |
ESC-03 | 54×0.5ml centrifuge tube | RT-25℃~100℃ |
ESC-04 | 96×0.2ml centrifuge tube | RT-25℃~100℃ |
ESC-05 | 96×0.2ml Elisa plate | RT-25℃~100℃ |
ES-06 | 35×2.0ml centrifuge tube | RT+5℃~100℃ |
ES-07 | 35×1.5ml centrifuge tube | RT+5℃~100℃ |
ES-08 | 54×0.5ml centrifuge tube | RT+5℃~100℃ |
ES-09 | 96×0.2ml centrifuge tube | RT+5℃~100℃ |
ES-10 | 96×0.2ml Elisa plate | RT+5℃~100℃ |