iDL8M-12L Intelligent Large Capacity Refrigerated Centrifuge

iDL8M-12L Compact refrigerated floor standing centrifuge is specially designed for universal use in blood banks, clinical laboratories, serology investigations, molecular biology, serum separation, and pharmaceutical applications, where repeatability, precision, and reliability of speed, time, temperature, acceleration, and deceleration are significant factors in obtaining perfect separation of distinct blood fractions.

Features of iDL8M-12L Intelligent Large Capacity Refrigerated Centrifuge

  1. 7 Inches color touch Panel. both shows the set parameters and operation parameters. An easy-going operator interface with standard English operating software, user can operate freely.
  2. Automatic open and close door lid system, with backup power in case of emergency power off, back up power automatically recharges when Machine powered on.
  3. All stainless steel internal and external structure, corrosion resistance and durable.
  4. Use the big Brand Compressor system and R404a Environmentally friendly refrigerant, with the accurate temperature control system.
  5. Can Store 99 programs. , Users can set 9 programs for daily operation use.
  6. With the self-diagnositc system and protection for imbalance, over-speed and over-temperature. Both automatic electronic lock and mechanical lock to ensure safety.
  7. Equipped with USB port, the program can be upgraded at any time, and download running data or error records (optional function)
  8. The swing rotor cover can be opened and fixed on door lid when machine open. And closed properly when door lid close.
DL8M-12L-LCD Display
LCD Display
DL8M-12L-Intelligent Type
Intelligent Type

Technical Parameters of iDL8M-12L Intelligent Large Capacity Refrigerated Centrifuge

ModeliDL8M-12LMax Speed8000r/min
Max RCF15200xgMax Capacity6×24000ml
Speed Accuracy±10r/minTimer Range0-99h 59 min
Temperature Range-20~+40℃control&drivemicroprocessor control
Acc/dec Rate0-9(Grade)Program Store99
Motor Power4KWRefrigerator Power2.2KW
Noise≤60dB(A)Power SupplyAC220V/380V 50Hz 35A
Weight500kgDimensions960×880×100mm(L×W×H)
Refrigeration System High-performance Compressor CFC-free Refrigeration System

Rotors of iDL8M-12L Intelligent Large Capacity Refrigerated Centrifuge

No.1 Swing rotor DL8M-12L No.1 Swing rotor Max Speed:4000r/min No.2 Swing rotor DL8M-12L No.2 Swing rotor Max Speed:4200r/min
Capacity:2×6×1000ml
12*400-500ml blood bag
Capacity:6×2400ml
Max RCF:5800xg Max RCF:5900xg
No.3 Swing rotor DL8M-12L No.3 Swing rotor Max Speed:4000r/min No.4 Angle rotor iDL8M-12L No.4 Angle rotor Max Speed:8000r/min
Capacity:24×200ml Capacity:6×1000ml
Max RCF:5900xg Max RCF:15200xg

iDL8M-12L Rotor Display

Application of iDL8M-12L Intelligent Large Capacity Refrigerated Centrifuge

Bio-Technology Company
Blood Bank Center
Bio-Technology Company
Bio-Technology Company
Chemistry Lab
Chemistry Lab
Bio-Pharmaceutical
Bio-Pharmaceutical