2500rpm (adjustable) Orbital Vortex Mixer MX-S MX-F
Vortex Mixers are ideal instruments for mixing liquid components in tubes, and resuspension of cells, using an eccentric mechanism. They are widely used in biological and chemical analysis applications for vigorous re-suspension of cells or chemical pellets in tubes up to 15 ml.
MX-S Vortex Mixer is a new type of vortex mixer, suitable for short-time (inching) or long-term continuous work; the maximum speed is 2500rpm/min, the motor is steplessly adjustable; there is a variety of vibrating head adapters to choose from (can be used for Eppendorf tubes, etc.); Silicon base, small and exquisite, super shockproof, suitable for high-speed work; easy installation of the vibrating head, stable and reliable products, eccentric ball bearing design.
Features of Vortex Mixer MX-S / MX-F
- Touch operation or continuous mode.
- Variable speed control from 0 to 2500rpm (MX-S).
- Fixed Speed 2500rpm (MX-F).
- Used for various mixing applications with optional adapters (MX-S).
- Specially designed vacuum suction feet for body stability.
- Robust aluminum-cast construction.


Specifications of Vortex Mixer MX-S / MX-F
Specifications |
MX-S |
MX-F |
Voltage |
110-120V/220-230V,50/60Hz |
|
Power |
60W |
60W |
Mixing motion |
Orbital |
Orbital |
Orbital diameter |
4mm |
4mm |
Motor type |
Shaded pole motor |
Shaded pole motor |
Motor rating input |
58W |
58W |
Motor rating output |
10W |
10W |
Speed range |
0-2500rpm |
2500rpm |
Speed display |
Scale |
– |
Run type |
Touch operation/Continuous |
|
Dimension[W×H×D] |
127×130×160mm |
127×130×160mm |
Weight |
3.5kg |
3.5kg |
Permissible ambient temperature |
5-40℃ |
5-40℃ |
Permissible relative humidity |
80%RH |
80%RH |
Protection class |
IP21 |
IP21 |
Accessory of Vortex Mixer MX-S / MX-F
Cat. No. |
P/N |
Descriptions |
Picture |
18900034 |
VT1.1 |
Standard top cup, for <Ø30mm tubes and small vessels |
|
18900044 |
VT1.2 |
Tube holding rod, used with VTI.3.1 to VTI.3.5 |
|
18900505 |
VT1.3 VT1.3.7 |
Universal top plate and vacuum suction foot package(include one top plate and four suction feet) |
|
18900020 |
VT1.3.1 |
Tube adapter, for 48 holes test tubes, Ø6mm, used with VT1.3/ VT1.2/PS1.1 |
|
18900021 |
VT1.3.2 |
Tube adapter, for 15 holes test tubes, Ø10mm, used with VT1.3/ VT1.2/PS1.1 |
|
18900022 |
VT1.3.3 |
Tube adapter, for 16 holes test tubes, Ø12mm , used with VT1.3/ VT1.2/PS1.1 |
|
18900023 |
VT1.3.4 |
Tube adapter, for 8 holes test tubes, Ø16mm, used with VT1.3/ VT1.2/PS1.1 |
|
18900024 |
VT1.3.5 |
Tube adapter, for 8 holes test tubes, Ø20mm, used with VT1.3/ VT1.2/PS1.1 |
|
18900043 |
VT1.3.6 |
Platform pad, for <Ø99mm tubes and small vessels |
|
18900158 |
VT1.3.7 |
Rubber vacuum suction foot with screw, 1pc |
|
Vortex Mixer MX-S / MX-F Display