What is a 4℃ Blood Bank Refrigerator?

Medical refrigerators have relatively advanced temperature control systems and advanced technology. They are generally used in hospitals. Some families can also keep medicines for refrigeration. They are subdivided into different categories according to different ways of use, such as medicine refrigerators, vaccine refrigerators, blood bank refrigerators, etc.

4℃ Blood Bank Refrigerator

Features of Blood Bank Refrigerator

  1. Accurate microprocessor controller to ensure consistent cabinet temperature of 4士1°C.
  2. Specially designed forced-air cooling system to ensure fast-free cabinet and good temperature uniformity.
  3. Three-layer toughened glass door with a heater to avoid condensation.
  4. 304 stainless steel inner chamber for friendly use and easy cleaning.
  5. Wide available voltage range: 187V~242V

MBC-4V500 Blood Bank Refrigerator

1306049404637929473

Parameter:

Model

MBC-4V500

Temperature Range

4±1℃

Cooling

4±1℃(Ambient Temp.32℃)

External Size(W×D×H)

710×800×1975(mm)

Internal size(W×D×H)

590×680×1442(mm)

Effect Capacity

500L

Net Weight

126kg

Rated Power

320W(220V,50Hz)

Insulation Layers

PU whole foamed

External Material

SUS

Internal Material

SUS

Out door

1

Lock

1

Test Hole

No

Compressor

1,all enclosed

Refrigerant

HFC

Alarm System

Temperature high/low alarm,abnormal door open alarm, power failure alarm

Accessory

Keys

MBC-4V1000 Blood Bank Refrigerator

Drawings of MBC-4V1000 Blood Bank Refrigerator

Parameter:

ModelMBC-4V1000
Temperature Range4±1℃
Cooling4±1℃(Ambient Temp32℃)
External Size(W×D×H)1200×750×1965(mm)
Internal size(W×D×H)1080×635×1412(mm)
Effect Capacity1000L
Net Weight152kg
Rated Power510W(220V,50Hz)
Insulation LayersPU whole foamed
External MaterialSUS
Internal MaterialSUS
Out door2
Lock2
Test HoleNo
Compressor1,all enclosed
RefrigerantHFC
Alarm SystemTemperature high/low alarm,abnormal door open alarm, power failure alarm
AccessoryKeys

safety

  • Safety door lock and controller sting password to prevent unauthorized access.
  • Build-in back-up battery to display termperature and to operate audible and visual alarm system for up to 72 hours without AC power.
  • Inner doors and auto on/off the cooling fan to prevent cold air from leaking out when the door is opening when a controller or two sensors failed.
  • Visual and audible alarm system: High/low temperature, power failure, sensor error, door ajar, low battery.
  • Power failure protection: turn on delay of the cooling system after power failure.
  • Controller error protection: the cooling system will remember the normal working cycle and keep working depending on this memory when a controller or two sensors failed.
  • Temperature printer: print current inside temperature automatically per 10 minutes.

Humanized Design

  • 4 casters, and 2 casters with stopper for easy moving and fixation.
  • 12 adjustable shelves and 36 blood baskets for easy use.
  • Special designed service-free drainage system ensures no water in the cabinet.
  • Standard 25mm test hole for easy connecting to temperature monitoring systems.
  • Automatic on/off LED light with manual switch on control panel.

Specification of Product

Model

MBC-4V108

MBC-4V208

MBC-4V368

MBC-4V658

MBC-4V1008

 

 

1422471851524943873

1422471908458426370

1422471939810848770

1422472005191659522

1422472005191659522

 

 

 

 

Performance

Temperature Range

4℃±1℃

4℃±1℃

4℃±1℃

4℃±1℃

4℃±1℃

Ambient Temperature

10~32℃

10~32℃

10~32℃

10~32℃

10~32℃

Controller

Microprocessor

Microprocessor

Microprocessor

Microprocessor

Microprocessor

Display

Digital Display

Digital Display

Digital Display

Digital Display

Digital Display

 

 

Refrigeration System

Compressor

1

1

1

1

1

Refrigerant

R134a

R134a

R134a

R134a

R134a

Cooling Type

Forced-air Cooling

Forced-air Cooling

Forced-air Cooling

Forced-air Cooling

Forced-air Cooling

Defrost Type

Frost Free

Frost Free

Frost Free

Frost Free

Frost Free

 

 

 

 

Alarm

High/low Temperature

Y

Y

Y

Y

Y

Power Failure

Y

Y

Y

Y

Y

Sensor Error

Y

Y

Y

Y

Y

Door Ajar

Y

Y

Y

Y

Y

 

 

 

 

Electrical Data

Power Supply (V/Hz)

220/50~60; 110/60

220/50~60; 110/60

220/50~60; 110/60

220/50~60; 110/60

220/50~60; 110/60

Rated Power (W)

160

200

325

364

513

Electrical Current (A)

0.6

0.8

2.2

2.42

2.37

Power Consumption

1.95 kwh/24h

2.22 kwh/24h

4.28 kwh/24h

6.31 kwh/24h

8.53 kwh/24h

 

 

 

 

 

Dimensions

Capacity

108L

208L

368L

685L

1008L

Interior Size (W*D*H)

432*462*478mm

432*462*978mm

785*565*1920mm

1100*454*1325mm

1100*684*1325mm

Exterior Size (W*D*H)

522*600*1050mm

522*600*1550mm

685*429*1380mm

1220*648*1885mm

1220*960*2130mm

Package Size (W*D*H)

640*740*1270mm

580*680*1700mm

890*650*2100mm

1300*735*2110mm

1300*960*2130mm

N.t./G.t.

73.5kg/95kg

96kg/120kg

128kg/135kg

201.5kg/256.5kg

264.5kg/334.5kg

 

 

 

 

 

 

Accessories

Caster

4

4

4

4

4

Lamp

LED

LED

LED

LED

LED

Shelf

2

3

4

12

12

Test Hole

1

1

1

1

1

Temperature Printer

1

1

1

1

1

Chart Recorder

Optional

Optional

Optional

Optional

Optional

Product Display

Blood Bank Refrigerator

Other Refrigerator & Freezer