GL-22MC/GL-21MC Floortype High Speed Refrigerated Centrifuge
Drawell GL-22MC/GL-21MC can meet high speed centrifuge and 3000ml large capacity. It has a refrigeration function and can be adapted to a variety of rotors. It is widely used in biochemistry, serum and blood stations, and other fields.
Features of High-Speed Refrigerated Centrifuge
Superior performance
Microcomputer controlled AC frequency variable motor drive, without toner power pollution.
Lower noise and less vibration, equipped with multiple types of rotors.
Efficiency has been greatly improved.
Easy operation
Large LCD with touch function display.
Programmable application.
Freely select various rotors.
Good effect
Freely set the acceleration time, and deceleration time, and automatically calculate RCF, which can achieve a good centrifugal effect.
Safe and reliable performance protection from over speed, over temperature, and imbalance.
Protection of automatic electronic or mechanical lock.
Ensure the safety of operators and machines.
Technical parameters of GL-22MC/GL-21MC
Model |
GL-21MC |
GL-22MC |
Max Speed |
21000r/min |
22000r/min |
Max RCF |
52300xg |
53000xg |
Max Capacity |
3000ml |
|
Speed Accuracy |
±20r/min |
|
Temp Range |
-20℃~+40℃ |
|
Temp Accuracy |
±1℃ |
|
The shortest Acc time |
1min30s(0~21000 r/min) |
1min35s(0~22000 r/min) |
The shortest Dec time |
1min40s(21000 r/min~0) |
1min45s(22000 r/min~0) |
Refrigeration system |
High-performance Compressor CFC-free Refrigeration System |
|
Timer Range |
0~23h 59min |
|
Motor |
Microprocessor control, Frequency conversion motor |
|
Noise |
≤60dB(A) |
|
Power Supply |
AC220V 50-60Hz 30A |
|
Dimension |
710×820×1200mm(L×W×H) |
|
Net Weight |
260kg |
Continuous Flow Rotor |
||||
NO. |
Max Speed |
Max RCF |
Full capacity |
Standard Flow |
1 |
14000r/min |
21500xg |
1000ml |
200-600ml/min |
2 |
8000r.min |
9500xg |
3000ml |
200-800ml/min |
3 |
16000r/min |
28100xg |
1000ml |
200-600ml/min |
4 |
10000r/min |
14800xg |
3000ml |
200-800ml/min |
Rotor
No.1 Angle Rotor |
Max Speed:22000r/min Max Capacity:12×1.5ml Max RCF:53000xg |
No.2 Angle Rotor |
Capacity:16/12×10ml Max Speed :21000r/min Max RCF:52300×g |
No.3 Angle Rotor |
Capacity:6×50ml Max Speed :20000r/min Max RCF:43000×g |
No.4 Angle Rotor |
Capacity:6×70/80ml Max Speed :15000r/min Max RCF:25700×g |
No.5 Angle Rotor |
Capacity:4×250/300ml Max Speed :12000r/min Max RCF:22470×g |
No.6 Angle Rotor |
Capacity:6×250ml Max Speed :12000r/min Max RCF:22470×g |
No.7 Angle Rotor |
Capacity:8×100ml Max Speed :14000r/min Max RCF:26952×g |
No.8 Angle Rotor |
Capacity:6×300ml Max Speed :12000r/min Max RCF:22470×g |
No.9 Angle Rotor |
Capacity:6×500ml Max Speed :10000r/min Max RCF:17800×g |
No.10 Angle Rotor |
Capacity:8×50ml Max Speed :18000r/min Max RCF:37600×g |
No.11 Swing Rotor |
Capacity:4×750/500ml Max Speed :4000r/min Max RCF:5470×g |
No.12 Swing Rotor |
Capacity:4×300/250ml Max Speed :4000r/min Max RCF:4210×g |
No.13 Microplate Rotor |
Capacity:2×2×96holes Max Speed :4000r/min Max RCF:2300×g |
|
|