DW-BP-9010A WDXRF Overview:

The wavelength dispersive X-ray fluorescence spectrometer (WDXRF) is a high-tech product developed by our company based on the experience and fruits of domestic R&D on similar instrument over years, and absorbing the international advanced technology, The technical performance indexes have reached the level of international similar products. It  can be used in any field that requires analysis of elements or compounds from Na to U, such as building materials (cement, glass, ceramics), metallurgy (iron and steel, non-ferrous metals), petroleum (trace elements such as S, Pb, etc.), chemical industry, geological mining, commodity inspection, quality inspection and even human trace elements inspection and so on. It is a reliable tool for macroanalysis and microanalysis. It is also used in universities and research institutes.

DW-BP-9010A is well-designed laboratory equipment that absorbs foreign advanced experience and integrates domestic technical advantages. Its excellent performance can meet the analysis requirements of different customer. The extremely attractive enables the users to benefit from the low-cost analysis process.

At present, our instruments have been widely used in the building materials (cement, glass, ceramics) industry, non-ferrous metals, steel, petrochemical and other fields. The application effect is good and meets the actual needs of users. 

Application scope:

● DW-BP-9010A  is very suitable for quality process control in large, medium and small cement plants (single and double kilns). It can be used for the analysis of primary and secondary oxides in raw materials (such as limestone, sand, bauxite, magnesite and other minerals);Determination of CaO, SiO2, Al2O3, Fe2O3, MgO, SO3, K2O, Na2O, Cl and other conventional elements in raw materials, clinker and cement.

● Application in steel industry: measuring: The element Si, Mn, P, S, Cu, A, Ni, Cr, Mo, V, Ti, W and Nb can be determined according to GB/T 223.79-2007.

● Application in other industries: Determination of S and P in petroleum, glass, ceramics, non-ferrous metals, mining, chemical industry, quality inspection, etc.

Feature:

● Highly automated analysis saves time and effort

Suitable for the research and management of raw materials, new materials, products, etc. It only takes about 3 minutes to complete the quantitative analysis of more than a dozen elements in one sample, as the high stability of the instrument fully ensures the automatic analysis.

The analysis results can be obtained quickly. After data processing, the quality inspection and specification judgment can be made, which can be applied to the production management analysis (especially bath analysis).

Quality control:

Quickly analyze the samples collected from the production line. The analysis result (proportion calculation) is used as the control data of raw material preparation for the feedback, which is used to improve and stabilize the quality

DW-BP-9010A Wavelength Dispersion WD-XRF

Advantage

Fixed multi-channel spectrometer: It is ingenious in the design of spectroscopic system, the collection and detection technology, and effectively improves the counting rate and stability of the instrument.

Intelligent fault detection device: It can monitor the instrument parameters in real time, control and protect the instrument and automatically alarm!

Advanced collimation technique: The spectral collimator adopts the advanced design technology of Bruker in Germany to optimize the optical path.

Ultra-short optical path: Using ultra-short optical path, the power of the X-ray tube is reduced, the service life of the X-ray tube is prolonged, and the structure of the cooling system is simplified. Greatly save maintenance costs. 

Stable regulating system of air flow density: It adopts American control component. It can automatically control the flow rate and density of air, greatly improves the control accuracy, the stability and repeatability of peak and element content detection.

Electrical pulse signal acquisition card: It adopts the international advanced electrical pulse acquisition signal algorithm to eliminate the background noise and interference peak, and improves the reliability and effectiveness of peak position determination accuracy and peak position drift correction.

Automatic safety protection device: It effectively protects the X-ray tube and high-voltage power supply.

The Analyzing crystal adopts plane and bent configuration of PET, InSb, Ge, LiF, etc., which ensures the measurement accuracy of each element. For Na and Mg elements, the most high-grade multi-layer crystal, it effectively protects the crystal from moisture.

Software: simple operation without any special requirements for operators.

Technical parameters

Element measuring range:  any 10 elements from 11Na~92U

X ray tubes: 400W, Be window, Rh target(Pd optional)

Tube cooling:  Professional circulation refrigeration, no need for cooling water.

High voltage power supply:400W ( 50kV8mA ) , tube voltage and current stability within 12h: better than 0.05 % .

Temperature control precision of thermostatic chamber:  set value ±0.1°C

Detector:  proportional flow detector, proportional counter, or scintillation counter.

Data processing system: 12-route 2048- channel independent pulse height analyzers

Vacuum system: independent pump station structure, double vacuum chamber, easy to maintain, the highest vacuum of the measurement room: less than 7Pa。

Detector gas flow system: using imported high-precision density flow control system, high-precision air flow density stability device, pressure stability is up to士0.01kPa.

220V AC power supply: 2kV A C purified and regulated current

Stability: ( 24 h)  ≤2%

Energy resolution of the counter: ≤40%

Linear counting of the counter: ≤1%

Measurement time of a single sample: (including vacuuming and sample change) ≤(2-5)min

Sample size:Ф40mm x10mm(H)

Sample analysis area: max 35mm2

Sample rotation speed: 30rpm

Software: qualitative analysis system automatic identification and analysis function (smooth, background correction)

Quantitative analysis system: all kinds of matrix correction, standard analysis, application template

Maintenance function: automatic diagnosis, remote diagnosis

DW-BP-9010A Wavelength Dispersion WD-XRF

Software feature:

(1)The self-developed Chinese(other language is also supported.) software system is suitable for Windows operating system. The software is simple and has no special requirements for operators;

(2)Intuitive operation interface, permit conducting multitasks simultaneously, man-machine dialogue, easy to modify and set various parameters;

(3)Using full spectrum detection, real-time intelligent correction of the instrument drift to the best running state;  

(4)Using the most advanced mathematical model algorithm to calibrate the work        

curve, easier procedure and more in line with the production process characteristics of users;

(5)Powerful database system support, to achieve a variety of matrix, background interference correction;

(6)  Equipped with online batching ratio feedback adjustment & calculation and

cement component measurement module for cement industry, statistical measurement of samples to help the process engineers to analyze the batching  changes;

(7)Powerful historical record inquiry function, master the change of production process dynamically at any time;

(8) Powerful self-diagnosis function, real-time monitoring of instrument status, automatic protection function;

(9)With the popular DCS communication protocol, which is convenient to share data with DCS system.

User-friendly operation interface

operation interface of DW-BP-9010A Wavelength Dispersion WD-XRF

User does not need professional knowledge; One-touch operation.

operation interface of DW-BP-9010A Wavelength Dispersion WD-XRF

Application case in cement industry

The wavelength dispersion XRF system is mainly composed of sample preparation equipment (including vibrating mill and tablet machine), wavelength dispersion spectrometer, computer system (including host, monitor, printer, keyboard and data communication interface), and other related equipment to constitute the WDXRF raw meal quality control system. The WDXRF is mainly used for the analysis on the chemical composition of raw materials in order to achieve the online automation control on the ratio of raw materials and ensure the standard deviation of raw meal feed into the kiln reaches the specified index; meanwhile, XRF can be used for the offline analysis on various raw materials, fuels, clinker and cement.  

This instrument is a simultaneous wavelength dispersive spectrometer, which can load more than 10 (including 10) analysis channels for simultaneous determination of multiple elements. The elemental analysis ranges from Na to U and 10 major elements in the cement, i.e., Ca, Fe, Si, Al, Na, Mg, S, K, Cl, P can be preset. The analysis speed is less than 2 minutes. The input power supply is single-phase 220/240vac, which also supply power to the PC and printer. 

Accuracy index of each element:

1303247591013847042

Raw meal test example in cement industry

Raw meal component analysis:  standard material repeated test 20 times.

Certificate No.:03203a-2008(Chinese standard)

Item

Component (%)

SiO2

Al2O3

Fe2O3

CaO

MgO

SO3

K2O

Na2O

Standard value

11.71

2.95

1.84

44.64

0.97

0.06

0.62

0.09

AVG value

11.7095

2.95

1.845

44.6495

0.9725

0.0595

0.6245

0.0885

Max value

11.72

2.97

1.86

44.67

0.99

0.06

0.63

0.09

Min value

11.69

2.94

1.83

44.63

0.96

0.05

0.61

0.08

Max-min

0.03

0.03

0.03

0.04

0.03

0.01

0.02

0.01

STDEV

0.00945

0.009733

0.0109

0.01276

0.008507

0.002236

0.007452

0.03663

Relative STDEV(%)

0.0807

0.3299

0.5955

0.0286

0.8748

3.7581

1.1951

4.1395

Clinker test case in cement industry

Cement clinker component analysis: standard material repeated test 20 times

Certificate No.:03204a(Chinese standard)

Item

Component (%)

SiO2

Al2O3

Fe2O3

CaO

MgO

SO3

K2O

Na2O

Standard value

21.66

4.76

3.83

64.35

1.73

0.51

1.11

0.13

AVG value

21.655

4.756

3.834

64.353

1.7335

0.5115

1.1118

0.129

Max value

21.67

4.77

3.85

64.37

1.75

0.52

1.13

0.14

Min value

21.64

4.74

3.82

64.34

1.72

0.50

1.10

0.12

Max-min

0.03

0.03

0.03

0.03

0.03

0.02

0.03

0.02

STDEV

0.011002

0.007539

0.009403

0.008645

0.11367

0.008127

0.008102

0.008522

Relative STDEV(%)

0.0508

0.1508

0.2453

0.0134

0.6557

1.5889

0.7287

6.6065

Silica test case

Using silica standard sample and compound standard sample as the calibration sample to set up Using silica standard sample and compound standard sample as the calibration sample to set up molten sample preparation determination of SiO2, Fe2O3, Al2O3, CaO, MgO style,, TiO2, MnO, P2O5, K2O Na2O primary and secondary components in silica. 

component(%)

SiO2

Fe2O3

Al2O3

CaO

MgO

K2O

TiO2

MnO

P2O5

Na2O

Measured value

95.523

1.532

0.231

0.892

0.321

0.732

0.052

0.421

0.0053

0.142

95.541

1.534

0.234

0.865

0.325

0.735

0.051

0.423

0.0058

0.143

95.483

1.548

0.214

0.843

0.345

0.736

0.053

0.425

0.0056

0.151

95.524

1.568

0.215

0.871

0.342

0.734

0.054

0.426

0.0057

0.145

95.514

1.543

0.258

0.861

0.362

0.752

0.052

0.452

0.0054

0.146

95.492

1.584

0.264

0.892

0.328

0.742

0.051

0.463

0.0052

0.148

95.567

1.512

0.254

0.872

0.329

0.762

0.053

0.425

0.0054

0.147

95.485

1.564

0.259

0.832

0.352

0.721

0.052

0.432

0.0058

0.154

95.564

1.527

0.243

0.852

0.345

0.751

0.052

0.428

0.0052

0.136

95.475

1.536

0.218

0.842

0.361

0.734

0.051

0.425

0.0055

0.144

AVG value

95.517

1.5448

0.239

0.8622

0.341

0.7339

0.0512

0.432

0.00549

0.1456

STDEV

0.0322

0.0216

0.0193

0.0204

0.0148

0.0120

0.0010

0.0140

0.0002

0.0050

Relative STDEV(%)

0.0348

1.3997

8.082

2.368

4.3321

1.6186

1.9087

3.2389

4.1581

3.4142

Application in steel industry

The wavelength dispersion XRF system is mainly composed of sample preparation equipment (including high frequency melting furnace and grinding machine), wavelength dispersion spectrometer, computer system (including host, monitor, printer, keyboard and data communication interface), and other related equipment to constitute the WDXRF analysis system applied in the steel industry. 

This instrument is a simultaneous wavelength dispersive spectrometer; over 10 analysis channels can be loaded for simultaneous determination of multiple elements. The elemental analysis ranges from Na to U and 8 major elements of iron ore, i.e., Ca, Mg, Si, Al, Mn, Ti, Ba, P of can be preset. The analysis speed is less than 2 minutes. The input power supply is single-phase 220/240vac, which also supply power to the PC and printer. 

Application cases in steel industry
Sinter: Repeat test 10 times for samples taken from the steel plant

No.

Sample No.

Fe(%)

CaO(%)

SiO2(%)

Al2O3(%)

MgO(%)

SO3(%)

1

0203

56.62

11.26

5.86

13.75

3.36

0.035

2

0203

56.65

11.25

5.87

13.74

3.35

0.036

3

0203

56.59

11.24

5.82

13.75

3.33

0.035

4

0203

56.66

11.23

5.84

13.75

3.35

0.034

5

0203

56.64

11.26

5.88

13.74

3.36

0.037

6

0203

56.63

11.22

5.89

13.75

3.35

0.036

7

0203

56.64

11.25

5.86

13.76

3.34

0.035

8

0203

56.67

11.23

5.85

13.78

3.35

0.038

9

0203

56.62

11.24

5.88

13.76

3.36

0.036

10

0203

56.65

11.26

5.85

13.75

3.34

0.035

Slag: Repeat test 10 times for samples taken from the steel plant

No.

Sample No.

Fe(%)

CaO(%)

SiO2(%)

MgO(%)

TiO2(%)

1

0305

11.41

53.23

6.81

8.97

0.85

2

0305

11.42

53.26

6.85

8.96

0.87

3

0305

11.42

53.22

6.83

8.92

0.85

4

0305

11.45

53.25

6.84

8.93

0.86

5

0305

11.43

53.28

6.88

8.96

0.87

6

0305

11.43

53.29

6.89

8.96

0.86

7

0305

11.45

53.26

6.82

8.95

0.85

8

0305

11.48

53.22

6.83

8.97

0.88

9

0305

11.42

53.23

6.89

8.99

0.90

10

0305

11.46

53.262

6.84

8.96

0.85