High & Low Speed Refrigerated Centrifuge TGD-22MC

Drawell TGD-22MC can meet high-speed centrifuge and 4*750 large capacity low-speed centrifuge. It has fast speed up and speeds down functions, the fastest speed-up time is 20 seconds, and the fastest speed downtime is 18 seconds. Not only can high-speed centrifugation, but also low-speed and large capacity centrifugation, one machine multi-function.

Features of TGD-22MC Benchtop High/Low-Speed Large Capacity Centrifuge

  1. Microprocessor control, speed control by frequency-conversion and CFC compressor.
  2. Maintenance-free Frequency-conversion motor without carbon dust pollution.
  3. Both High speed angle rotor and low speed swing rotor can meet different requirement
  4. Safety Interlock system that prevents opening the centrifuge lid during running.
  5. 10 programs can be stored, and quickly recall the last used program.
  6. Imbalance sensor, Over speed and over temperature cut off
  7. Easy operation, LCD touch screen, compressor control.
  8. With Emergency lid lock release, in case of power off.
High & Low Speed Refrigerated centrifuge TGD-22MC

Technical Parameters of Refrigerated Centrifuge TGD-22MC

ModelTGD-22MCSpeed  Accuracy±50r/min
Max Speed22000r/minTimer Range0~99min
Max RCF34700xgTemp Range-20℃~﹢40℃
DisplayLCD displayMax Capacity4×750ml
Noise≤60dB(A)Power SupplyAC220v&110V 50Hz 18A
Weight100kgDimension656x835x45mm

Rotor


图片4 8No.1

Max Speed:22000r/min

Capacity:12×1.5/2.2ml AR

Max RCF:34700xg

图片6 副本No.2

Max Speed:16500r/min

Capacity:8/10/12×5ml

Max RCF:18360xg

图片2 18No.3

Max Speed:12000r/min

Capacity:12×10ml AR

Max RCF:14800xg

图片2 14No.4

Max Speed:13500r/min

Capacity:24×1.5/2.2ml AR

Max RCF:17000xg

图片5 4No.5

Max Speed:13500r/min

Capacity:18×0.5ml AR

Max RCF:17000xg

图片1 17No.6

Max Speed:14000r/min

Capacity:36×1.5/2.2ml AR

Max RCF:18200xg

图片7 副本No.7

Max Speed:13000r/min

Capacity:6×50ml AR

Max RCF:17940xg

图片8 2No.8 

Max Speed:10000r/min

Capacity:4×100ml AR

Max RCF:9800xg

图片9 2No.9

Max Speed:4000r/min

Capacity:2×2×48 holes

Max RCF:1760xg

图片3 10No.10

Max Speed:15000r/min

Capacity:6×30ml AR

Max RCF:23120xg

图片4 10No.11

Max Speed:13000r/min

Capacity:6×15ml AR

Max RCF:15100xg

图片5 5No.12

Max Speed:5000r/min

Capacity:12×15/10ml

Max RCF:4390xg

图片6 4No.13

Max Speed:4000r/min

Capacity:48×10/15/7/5ml SR

Max RCF:3020xg

图片7 3No.14

Max Speed:4000r/min

Capacity:4×250ml SR

Max RCF:3020xg

图片8 3No.15

Max Speed:4000r/min

Capacity:6×500ml SR

Max RCF:4390xg

图片9 3No.16

Max Speed:4000r/min

Capacity:4×500/750ml SR

Max RCF:3600xg


Other Benchtop Refrigerated Centrifuge