Biochemistry Analyzer

What is Biochemistry Analyzer?

The Clinical Biochemistry Analyzer is an instrument that uses the pale yellow supernatant portion (serum) of centrifuged blood sample or a urine sample and induces reactions using reagents to measure various components, such as sugar, cholesterol, protein, enzyme, etc. The most common test method is photometry. The sample is mixed with the appropriate reagent to produce a reaction that results in color. The concentration of the analyte determines the strength of the color produced. Our biochemical analyzers are divided into fully automatic and semi-automatic biochemical analyzers.

TC6090

Features of Biochemistry Analyzer

  1. Fully automatic, discrete, random STAT function.
  2. Online test items.
  3. Analysis Method: end-point, kinetic, two-point, double-reagents, double-wavelength, multi-standard, etc, open to various reagents.
  4. Data Processing.
  5. Various QC managements, insert QC randomly; save, display & print QC chart; define different QC in advance.
  6. Calibration: linear/nonlinear multi-point calibration.
  7. Re-test: retest the sample automatically when the result is out of the linearity range or the sample is not sufficient
  8. Cleaning System,8-step automatic washing, automatic cuvette dry function.

Applications of Biochemistry Analyzer

The biochemical analyzer can be used in hospital laboratories for various tests, such as clinical blood routine, myocardial enzyme spectrum, blood lipid, liver function, kidney function, albumin detection, blood sugar detection and other routine biochemical indicators, or detection of enzymes and muscle in blood Anhydride levels. Clinically, some types of biochemical analyzers can be used to measure antigen-antibody interactions in biochemical reactions. Such as:

1. Liver function test: total bilirubin, direct bilirubin, total protein, albumin, alanine aminotransferase, aspartate aminotransferase, γ-glutamyltransferase, alkaline phosphatase.

2. Examination of renal function: urea (UREA), creatinine (CREA), uric acid (UA).

3. Blood lipids: total cholesterol (TC), triglyceride (TG), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), apolipoprotein (ApoA1), apolipoprotein ( ApoB).

4. Blood sugar: Glucose (Glu), glycosylated hemoglobin (HbA1C) detection.

5. Three items of rheumatism: C-reactive protein, antistreptolysin O, and rheumatoid factor.

Application of Biochemistry Analyzer

How to Choose the Biochemistry Analyzer?

1)What are the differences between our models?

The main reason is that the complexity of the instruments is inconsistent, and there are differences between automatic and semi-automatic.

2)Testing speed

Testing speed is one of the important parameters for users to choose a biochemical analyzer. 

3)Optical parameters

In addition to the characteristics of spectroscopic technology, the instrument in a certain wavelength range of monochromatic light wavelength (or filter) number should be able to meet the needs of laboratory testing work, usually in the wavelength range of 300 ~ 800 nm, the number of fixed wavelengths should be more than 11.

4)Reagent position and sample loading

The fully automated biochemical analyzers used in clinical laboratories now generally use multi-channel analysis. Biochemistry analyzers can be loaded with sample trays or sample racks.

5)Environmental requirements

To ensure the normal use of biochemical analyzers, there are certain requirements for their installation environment, such as temperature, humidity, water quality and water (discharge), power supply power, and use of space.

Order Process

order process

Why Choose Us?

  1. Rich categories
  2. The products are market-oriented and exported to many countries in the world
  3. Perfect sales system, efficient and fast after-sales service
  4. On-time delivery rate reaches 100%
  5. High-cost performance

FAQ

– We are a factory.

  • Usually, MOQ is 1 piece.
  • The general MOQ differs greatly between different products if there is no stock. But the quantity still can be negotiated.

– Sample is available, but we do not provide free samples.

– OEM service is available with customer’s brand.

– We accept the payment by L/C, T/T, Paypal, Western Union, etc.

– Generally, it will take 7-15 working days after receiving your advance payment. Depend on the quantity.

– We could provide Online instruction; Real-time support by video call or voice chat; During warranty time, we can send product accessories when you need them for free; Technical guidance is free and ready forever.

– 1 year. it can be negotiated if you need an extended warranty.

– Email: [email protected]

– Tel.: 008613320353102

Related Products Recommendation